Symptoms
Gjenopprettingen for spfile mislykkes med følgende feil:
RMAN> connect ******** 2> 3> CREATE SPFILE RMAN-00571: =========================================================== RMAN-00569: =============== ERROR MESSAGE STACK FOLLOWS =============== RMAN-00571: =========================================================== RMAN-00558: error encountered while parsing input commands RMAN-01009: syntax error: found "spfile": expecting one of: "catalog, global, restore, script, virtual" RMAN-01007: at line 3 column 8 file: /tmp/rman_script_xxxx_8368
Cause
Problemet er med Oracle-versjonen.
For Oracle 11g kreves RMAN-setningsdelen for å legge til sql i setningsdelen .
For Oracle 12c og 19c er det ikke nødvendig. Eksempel:
RMAN> connect ******** 2> 3> sql "CREATE SPFILE"
Resolution
Dette er løst permanent i PowerProtect Data Manager 19.15.
Den nåværende løsningen er å bruke CLI til å gjenopprette SPFILE først, og deretter gjøre resten Alternativ gjenoppretting i brukergrensesnittet uten SPFILE.
Den nåværende løsningen er å bruke CLI til å gjenopprette SPFILE først, og deretter gjøre resten Alternativ gjenoppretting i brukergrensesnittet uten SPFILE.