[PowerScale]PowerScale 歸檔和混合節點回報假性外部電源故障

Summary: PowerScale 歸檔和混合節點偶爾會回報外部電源供應器故障,但並未發生外部電源問題。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerScale 歸檔或混合式機型節點 (A300/A3000/H700/H7000) 回報節點電源供應器上的一對外部故障:
 

107.1598576 04/02 03:00 C    107  524519         Power Supply Status: External Fault
107.1598575 04/02 03:00 C    107  524520         Power Supply Status: External Fault

相同機架中的其他節點未報告問題。檢查資料中心電源,機架供電沒有問題。此事件不會造成服務中斷,且節點仍保持線上。

Cause

電源供應器製造商已判定這是韌體問題。

Resolution

此訊息不代表硬體問題,可忽略此訊息。更換電源供應器無法解決問題。節點韌體套件 (NFP) 13.1.3 及更新版本提供解決此問題的更新韌體。

Affected Products

PowerScale Archive A300, PowerScale Archive A3000, PowerScale Hybrid H700, PowerScale Hybrid H7000