[PowerScale]PowerScale 歸檔和混合節點回報假性外部電源故障
Summary: PowerScale 歸檔和混合節點偶爾會回報外部電源供應器故障,但並未發生外部電源問題。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
PowerScale 歸檔或混合式機型節點 (A300/A3000/H700/H7000) 回報節點電源供應器上的一對外部故障:
107.1598576 04/02 03:00 C 107 524519 Power Supply Status: External Fault 107.1598575 04/02 03:00 C 107 524520 Power Supply Status: External Fault
相同機架中的其他節點未報告問題。檢查資料中心電源,機架供電沒有問題。此事件不會造成服務中斷,且節點仍保持線上。
Cause
電源供應器製造商已判定這是韌體問題。
Resolution
此訊息不代表硬體問題,可忽略此訊息。更換電源供應器無法解決問題。節點韌體套件 (NFP) 13.1.3 及更新版本提供解決此問題的更新韌體。
Affected Products
PowerScale Archive A300, PowerScale Archive A3000, PowerScale Hybrid H700, PowerScale Hybrid H7000Article Properties
Article Number: 000224058
Article Type: Solution
Last Modified: 19 Sep 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.