PowerStore:系统检查检测孤立的中转连接对象

Summary: 运行状况检查可确定数据路径 (DP) 中是否存在传输连接对象。如果使用“验证和更新”选项勾选远程系统,则可能会生成这些信息。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

如果系统检查在 DP 中检测到任何中转连接对象,则会显示以下错误消息:“There are orphan transit connection objects <Object ID>.(KB#000226767)”

如果存在这种情况,则在 PowerStore Manager 的 Monitoring 窗口中按“System Check”按钮将输出以下结果:
图像

如果存在这种情况,则运行服务脚本 svc_health_check 产生以下输出:
[BSC:cyc@ABCDEFG-A ~]$ svc_health_check run -rhc transit_connection_check
/usr/lib/python2.7/site-packages/requests/__init__.py:91: RequestsDependencyWarning: urllib3 (1.26.18) or chardet (3.0.4) doesn't match a supported version!
  RequestsDependencyWarning)
Name                               Location  Status     Description
Datapath Transit Connection Obje.. node_a    Failed     There are orphan transit connection objects 2aa059b7-a073-46cd-bffe-5ddfa8c1ecce:29:0. (KB#000226767)

SUMMARY Status: Failed
   Passed:      0
   Failed:      1
   Total:       1

 

Cause

如果在两个 PowerStore 群集之间配置复制,则重命名群集并在远程系统连接上执行“验证和更新”操作可能会导致节点重新启动。

Resolution

请联系技术支持以获得帮助。请提及此知识库文章以获得加急服务。