Summary: Errore irreversibile del bus BCM5719 PowerEdge R860 con PCI1360 e PCI1318

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Gli utenti potrebbero riscontrare errori irreversibili del bus per PCI1360 e PCI1318 quando il sistema funziona correttamente.

Il registro del ciclo di vita mostra quanto segue:

2024-07-10 05:14:39    61    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-10 05:14:42    62    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-10 05:14:43    63    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:14:43    64    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-10 05:14:46    66    PST0209    System BIOS has halted due to Non-Maskable Interrupt (NMI).
2024-07-10 05:48:04    92    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:48:20    94    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-13 01:59:23    115    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:25    116    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-13 01:59:29    119    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-13 01:59:31    121    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:31    122    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:49    198    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:50    199    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:56    203    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:57    204    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:49:01    208    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:23:42    236    SEC0033    The chassis is open while the power is off.
2024-07-17 00:32:30    243    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:32    244    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:34    247    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:32:37    249    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:38    250    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:47    254    CPU0704    CPU 4 machine check error detected.
2024-07-17 00:33:08    268    CPU0704    CPU 1 machine check error detected.

Nella figura di avvio è presente un errore come indicato di seguito, indicante slot1 BCM5719 scheda di rete:

Errore PCIe

Risoluzione dei problemi:

  1. Il BIOS e il firmware iDRAC sono aggiornati alla versione più recente.
  2. L'utente dispone di più unit server, ma solo questo server presenta l'errore irreversibile del bus. Spegnere e riaccendere l'alimentazione CA e il problema persiste.
  3. Ricollocare il BCM5719 Broadcom NetXtreme e il problema rimane.

Cause

Si è verificato un BCM5719 problema di instabilità della scheda di rete.

Resolution

Seguire le azioni consigliate nell'evento stesso.

Eseguire una o tutte le operazioni riportate di seguito:

  1. Assicurarsi che il dispositivo, il BIOS e iDRAC siano aggiornati alla versione più recente del firmware.
  2. Se si è verificato un problema del batch, aggiornare la versione del sistema operativo per patch o hotfix. Aggiornare i driver del dispositivo.
  3. Spegnere e riaccendere l'alimentazione CA.
  4. Se possibile, accertarsi che i cavi siano instradati e collegati correttamente. Rimuovere e reinstallare il dispositivo.
  5. Disabilitare lo slot1 nel BIOS oppure il modo migliore è scambiarlo con un altro slot PCIe per il test. Se il problema si ripete in seguito a Broadcom NetXtreme BCM5719, si consiglia di sostituire questa scheda di rete.