PowerEdge: R860 BCM5719 버스 PCI1360 및 PCI1318 치명적인 오류

Summary: PowerEdge R860 BCM5719 버스 PCI1360 및 PCI1318 시 치명적인 오류 발생

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

시스템이 제대로 작동할 때 PCI1360 및 PCI1318에 치명적인 버스 오류가 발생할 수 있습니다.

수명주기 로그에는 다음과 같이 표시됩니다.

2024-07-10 05:14:39    61    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-10 05:14:42    62    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-10 05:14:43    63    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:14:43    64    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-10 05:14:46    66    PST0209    System BIOS has halted due to Non-Maskable Interrupt (NMI).
2024-07-10 05:48:04    92    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:48:20    94    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-13 01:59:23    115    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:25    116    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-13 01:59:29    119    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-13 01:59:31    121    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:31    122    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:49    198    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:50    199    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:56    203    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:57    204    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:49:01    208    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:23:42    236    SEC0033    The chassis is open while the power is off.
2024-07-17 00:32:30    243    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:32    244    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:34    247    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:32:37    249    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:38    250    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:47    254    CPU0704    CPU 4 machine check error detected.
2024-07-17 00:33:08    268    CPU0704    CPU 1 machine check error detected.

다음과 같이 부팅 그림에 네트워크 카드의 슬롯 1을 나타내는 오류가 BCM5719.

PCIe 오류

문제 해결:

  1. BIOS 및 iDRAC 펌웨어가 최신 버전입니다.
  2. 사용자에게 여러 장치 서버가 있지만 이 서버에만 버스 치명적 오류가 있습니다. AC 전원을 껐다 켜도 문제가 남아 있습니다.
  3. Broadcom NetXtreme BCM5719를 다시 장착해도 문제가 남아 있습니다.

Cause

BCM5719 네트워크 카드가 불안정한 문제가 발생했습니다.

Resolution

이벤트 자체에 권장되는 조치를 따릅니다.

아래 단계 중 하나 또는 모두를 수행합니다.

  1. 디바이스, BIOS 및 iDRAC가 최신 펌웨어로 업데이트되었는지 확인합니다.
  2. 배치 문제가 발생한 경우 패치 또는 핫픽스에 대한 OS 버전을 업데이트하십시오. 디바이스 드라이버를 업데이트합니다.
  3. AC 전원을 껐다 켭니다.
  4. 가능한 경우 케이블이 올바르게 라우팅 및 연결되어 있는지 확인합니다. 디바이스를 제거했다가 다시 설치합니다.
  5. BIOS에서 slot1을 비활성화하거나 테스트를 위해 다른 PCIe 슬롯과 교체하는 것이 가장 좋습니다. 문제가 Broadcom NetXtreme BCM5719에서 발생하는 경우 이 네트워크 카드를 교체하는 것이 좋습니다.

Affected Products

OEMR R860, PowerEdge R860, PowerFlex custom node R860
Article Properties
Article Number: 000227163
Article Type: Solution
Last Modified: 28 Aug 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.