PowerEdge: R860 BCM5719 feilslått buss med PCI1360 og PCI1318
Summary: PowerEdge R860 BCM5719 uopprettelig feil i bussen med PCI1360 og PCI1318
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Brukere kan støte på fatale bussfeil for PCI1360 og PCI1318 når systemet fungerer som det skal.
Livssyklusloggen viser følgende:
2024-07-10 05:14:39 61 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-10 05:14:42 62 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-10 05:14:43 63 NIC100 The NIC in Slot 1 Port 1 network link is down. 2024-07-10 05:14:43 64 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-10 05:14:46 66 PST0209 System BIOS has halted due to Non-Maskable Interrupt (NMI). 2024-07-10 05:48:04 92 NIC100 The NIC in Slot 1 Port 1 network link is down. 2024-07-10 05:48:20 94 NIC100 The NIC in Slot 1 Port 1 network link is down. 2024-07-13 01:59:23 115 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-13 01:59:25 116 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-13 01:59:29 119 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-13 01:59:31 121 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-13 01:59:31 122 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-16 22:48:49 198 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-16 22:48:50 199 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-16 22:48:56 203 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-16 22:48:57 204 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-16 22:49:01 208 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-17 00:23:42 236 SEC0033 The chassis is open while the power is off. 2024-07-17 00:32:30 243 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-17 00:32:32 244 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-17 00:32:34 247 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-17 00:32:37 249 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-17 00:32:38 250 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-17 00:32:47 254 CPU0704 CPU 4 machine check error detected. 2024-07-17 00:33:08 268 CPU0704 CPU 1 machine check error detected.
Det er en feil i oppstartstallet som indikerer spor 1 BCM5719 nettverkskort:

Feilsøking:
- BIOS- og iDRAC-fastvare er siste versjon.
- Brukeren har flere enhetsservere, men bare denne serveren har den alvorlige bussfeilen. Utfør en vekselstrømsyklus, og problemet vedvarer.
- Sett inn Broadcom NetXtreme på nytt BCM5719, og problemet gjenstår.
Cause
Det har oppstått et ustabilt problem BCM5719 nettverkskortet.
Resolution
Følg de anbefalte handlingene i selve hendelsen.
Gjør ett eller alle trinnene nedenfor:
- Kontroller at enheten, BIOS og iDRAC er oppdatert til den nyeste fastvaren.
- Hvis det oppstod et satsvis problem, oppdaterer du OS-versjonen for korrigeringsfiler eller hurtigreparasjoner. Oppdater enhetsdriverne.
- Utfør en vekselstrømsyklus.
- Hvis mulig, kontroller at kablene er riktig ført og tilkoblet. Fjern og installer enheten på nytt.
- Deaktiver spor 1 i BIOS, eller den beste måten er å bytte til et annet PCIe-spor for testing. Hvis problemet følger Broadcom NetXtreme-BCM5719, kan du vurdere å bytte ut dette nettverkskortet.
Affected Products
OEMR R860, PowerEdge R860, PowerFlex custom node R860Article Properties
Article Number: 000227163
Article Type: Solution
Last Modified: 28 Aug 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.