PowerEdge. Неустранимая ошибка шины R860 BCM5719 при использовании PCI1360 и PCI1318

Summary: PowerEdge R860 BCM5719 случае неустранимой ошибки шины с PCI1360 и PCI1318

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

При нормальной работе системы пользователи могут столкнуться с неустранимыми ошибками шины для PCI1360 и PCI1318.

Журнал жизненного цикла отображается следующим образом:

2024-07-10 05:14:39    61    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-10 05:14:42    62    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-10 05:14:43    63    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:14:43    64    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-10 05:14:46    66    PST0209    System BIOS has halted due to Non-Maskable Interrupt (NMI).
2024-07-10 05:48:04    92    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:48:20    94    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-13 01:59:23    115    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:25    116    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-13 01:59:29    119    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-13 01:59:31    121    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:31    122    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:49    198    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:50    199    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:56    203    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:57    204    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:49:01    208    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:23:42    236    SEC0033    The chassis is open while the power is off.
2024-07-17 00:32:30    243    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:32    244    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:34    247    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:32:37    249    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:38    250    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:47    254    CPU0704    CPU 4 machine check error detected.
2024-07-17 00:33:08    268    CPU0704    CPU 1 machine check error detected.

На рисунке загрузки указана ошибка, указывающая на разъем 1 BCM5719 сетевой карты:

Ошибка PCIe

Поиск и устранение неполадок:

  1. Версия микропрограммы BIOS и iDRAC новейшая.
  2. У пользователя есть несколько серверов юнитов, но только на этом сервере есть неустранимая ошибка шины. Выполните цикл выключения и включения питания переменного тока, но проблема не исчезнет.
  3. Переустановите BCM5719 Broadcom NetXtreme, и проблема исчезнет.

Cause

Возникла проблема нестабильной работы сетевой платы BCM5719.

Resolution

Выполните рекомендуемые действия в самом событии.

Выполните одно или все указанные ниже действия.

  1. Убедитесь, что микропрограмма устройства, BIOS и iDRAC обновлены до последней версии.
  2. Если возникла пакетная проблема, обновите версию ОС, чтобы установить исправления. Обновите драйверы устройства.
  3. Выключите и снова включите питание переменного тока.
  4. По возможности убедитесь, что кабели правильно проложены и подключены. Снимите и снова установите устройство.
  5. Отключите разъем 1 в BIOS или поменяйте его местами с другим разъемом PCIe для проверки. Если проблема возникла после BCM5719 Broadcom NetXtreme, возможно, потребуется заменить эту сетевую плату.