PowerEdge: R860 BCM5719 buss Allvarligt fel med PCI1360 och PCI1318
Summary: Allvarligt fel på PowerEdge R860 BCM5719-bussen med PCI1360 och PCI1318
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Användare kan stöta på allvarliga bussfel under PCI1360 och PCI1318 när systemet fungerar som det ska.
Livscykelloggen visar följande:
2024-07-10 05:14:39 61 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-10 05:14:42 62 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-10 05:14:43 63 NIC100 The NIC in Slot 1 Port 1 network link is down. 2024-07-10 05:14:43 64 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-10 05:14:46 66 PST0209 System BIOS has halted due to Non-Maskable Interrupt (NMI). 2024-07-10 05:48:04 92 NIC100 The NIC in Slot 1 Port 1 network link is down. 2024-07-10 05:48:20 94 NIC100 The NIC in Slot 1 Port 1 network link is down. 2024-07-13 01:59:23 115 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-13 01:59:25 116 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-13 01:59:29 119 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-13 01:59:31 121 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-13 01:59:31 122 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-16 22:48:49 198 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-16 22:48:50 199 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-16 22:48:56 203 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-16 22:48:57 204 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-16 22:49:01 208 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-17 00:23:42 236 SEC0033 The chassis is open while the power is off. 2024-07-17 00:32:30 243 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-17 00:32:32 244 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-17 00:32:34 247 PCI1318 A fatal error was detected on a component at bus 7 device 5 function 0. 2024-07-17 00:32:37 249 PCI1360 A bus fatal error was detected on a component at slot 1. 2024-07-17 00:32:38 250 PCI1318 A fatal error was detected on a component at bus 8 device 0 function 0. 2024-07-17 00:32:47 254 CPU0704 CPU 4 machine check error detected. 2024-07-17 00:33:08 268 CPU0704 CPU 1 machine check error detected.
Det finns ett fel i uppstartsfiguren enligt följande som indikerar kortplats 1 BCM5719 nätverkskortet:

Felsökning:
- Den fasta programvaran för BIOS och iDRAC är den senaste versionen.
- Användaren har flera enhetsservrar, men det är bara den här servern som har det allvarliga bussfelet. Om du startar om nätströmmen kvarstår problemet.
- Sätt tillbaka Broadcom NetXtreme-BCM5719 så kvarstår problemet.
Cause
Ett BCM5719 instabilt problem med nätverkskortet har uppstått.
Resolution
Följ de rekommenderade åtgärderna i själva händelsen.
Gör ett eller alla steg nedan:
- Se till att enheten, BIOS och iDRAC är uppdaterade till den senaste fasta programvaran.
- Om ett batchproblem uppstår uppdaterar du OS-versionen för korrigeringar eller snabbkorrigeringar. Uppdatera enhetsdrivrutinerna.
- Utför en omstart.
- Kontrollera om möjligt att kablarna är korrekt dragna och anslutna. Ta bort och installera om enheten.
- Inaktivera kortplats 1 i BIOS eller så byter du till en annan PCIe-kortplats för testning. Om problemet följer Broadcom NetXtreme-BCM5719 kan du överväga att byta ut det här nätverkskortet.