PowerEdge: PCI1360 ve PCI1318 ile R860 BCM5719 Veri Yolu Önemli Hata

Summary: PowerEdge R860 PCI1360 ve PCI1318 ile BCM5719 veriyolu önemli hatası

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Kullanıcılar, sistem düzgün çalışırken PCI1360 ve PCI1318 için önemli veri yolu hatalarıyla karşılaşabilir.

Yaşam döngüsü günlüğü aşağıdaki gibi gösterilir:

2024-07-10 05:14:39    61    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-10 05:14:42    62    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-10 05:14:43    63    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:14:43    64    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-10 05:14:46    66    PST0209    System BIOS has halted due to Non-Maskable Interrupt (NMI).
2024-07-10 05:48:04    92    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-10 05:48:20    94    NIC100    The NIC in Slot 1 Port 1 network link is down.
2024-07-13 01:59:23    115    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:25    116    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-13 01:59:29    119    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-13 01:59:31    121    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-13 01:59:31    122    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:49    198    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:50    199    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:48:56    203    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-16 22:48:57    204    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-16 22:49:01    208    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:23:42    236    SEC0033    The chassis is open while the power is off.
2024-07-17 00:32:30    243    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:32    244    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:34    247    PCI1318    A fatal error was detected on a component at bus 7 device 5 function 0.
2024-07-17 00:32:37    249    PCI1360    A bus fatal error was detected on a component at slot 1.
2024-07-17 00:32:38    250    PCI1318    A fatal error was detected on a component at bus 8 device 0 function 0.
2024-07-17 00:32:47    254    CPU0704    CPU 4 machine check error detected.
2024-07-17 00:33:08    268    CPU0704    CPU 1 machine check error detected.

Önyükleme şeklinde aşağıdaki gibi bir hata var, bu hata ağ kartı BCM5719 yuva1'i gösteriyor:

PCIe hatası

Sorun Giderme:

  1. BIOS ve iDRAC bellenimi en son sürümdür.
  2. Kullanıcının birden fazla birim sunucusu var ancak yalnızca bu sunucuda önemli veri yolu hatası var. AC gücünü kapatıp açtığınızda sorun devam eder.
  3. Broadcom NetXtreme BCM5719 ı yeniden yerleştirin ve sorun devam etsin.

Cause

Bir BCM5719 ağ kartı kararsız sorunu oluştu.

Resolution

Olayın kendisinde önerilen eylemleri uygulayın.

Aşağıdaki adımlardan birini veya tümünü uygulayın:

  1. Aygıtın, BIOS'un ve iDRAC'ın en son ürün yazılımına güncelleştirilmiş olduğundan emin olun.
  2. Bir toplu sorun oluşursa yamalar veya düzeltmeler için işletim sistemi sürümünü güncelleştirin. Aygıt sürücülerini güncelleyin.
  3. AC güç döngüsü gerçekleştirin.
  4. Mümkünse kabloların doğru şekilde yönlendirildiğinden ve bağlandığından emin olun. Aygıtı çıkarın ve yeniden takın.
  5. BIOS'ta yuva 1'i devre dışı bırakın ya da en iyi yol, test için diğer PCIe yuvasıyla değiştirmektir. Sorun Broadcom NetXtreme BCM5719 de devam ediyorsa bu ağ kartını değiştirmeyi düşünebilirsiniz.

Affected Products

OEMR R860, PowerEdge R860, PowerFlex custom node R860
Article Properties
Article Number: 000227163
Article Type: Solution
Last Modified: 28 Aug 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.