Problem
Feil ved svitsjporter uten kobling og LED ned. Noen ganger blir en bryter sittende fast i en oppstartssløyfe. Nedenfor er feilene som logges på de mislykkede enhetene:AQuantia PHY 0x1 unknown sysIntfCurrentMode = 1 AQuantia PHY 0x1 unknown sysIntfCurrentMode = 1 AQuantia PHY 0x1 unknown sysIntfCurrentMode = 1 AQuantia PHY 0x1 unknown sysIntfCurrentMode = 1 AQuantia PHY 0x1 unknown sysIntfCurrentMode = 1 PTB file to be loaded on PHYID:0x1 device:0x4 Failed to load PTB file on PHYID:0x1, aq_rv=246 BRCM:hpcAqPhyReset: Failed to load PTB file on BCMport:47 phy addr:0x1
Merk: Meldingene vises ved oppstart i feiltilstanden. Hvis vi kjører noen grensesnittrelaterte kommandoer etter oppstart, vil den også vise disse feilene på konsollen.
Berørte plattformer: N2248PX, N2248X, N2224PX, N2224X
Rot-årsak
PHY-degradering (feil på SPI-grensesnitt) forårsaker lesefeil fra SPI-flash. Kan ikke lese PHY firmware programmering fra SPI Flash etter anslagsvis 1,5 år i feltet.Resolution (oppløsning)
Oppdater OS6-fastvareversjonen til 6.6.3.15 eller 6.7.1.1 og nyere for å løse problemet.Finn den nyeste programvaren her:
PowerSwitch N2200-ON-serien – drivere og nedlastinger
Affected Products
PowerSwitch N2200-ON SeriesArticle Properties
Article Number: 000228026
Article Type: How To
Last Modified: 23 Aug 2024
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.