PowerProtect Data Manager File System Agent 註冊失敗,因為反向 IP 查詢組態問題

Summary: PowerProtect Data Manager 檔案系統代理程式註冊因反向 IP 查詢組態問題而失敗。如果未配置反向IP查找,則新安裝後代理註冊將失敗。若要解決此問題,請在 DNS 伺服器上設定反向 IP 查詢或暫時修改主機檔案。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

新安裝

後的 PowerProtect Data Manager File System 代理程式註冊失敗 從 PowerProtect Data Manager UI>應用程式代理程式>註冊狀態中,會在接受憑證後顯示失敗。  

狀態為「正在接受憑證」的應用程式代理程式的螢幕擷取畫面

狀態為「失敗」的應用程式代理程式的螢幕截圖

C:\Program Files\DPSAPPS\AgentService\logs\OpAgentSvc-******.log,它顯示以下內容 PPDM IpCheck validation failed/greetings call

[2024-10-21 03:53:05,643 GMT| 2024-10-21 11:53:05,643506 | DBGHTTPSERVER| PID-2796| TID-3564| INFO] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-checkIP()-Line 361- Could not fetch the host details for the address ppdm.local.com
[2024-10-21 03:53:05,643 GMT| 2024-10-21 11:53:05,643506 | DBGHTTPSERVER| PID-2796| TID-3564| INFO] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-checkIP()-Line 362- PPDM IpCheck validation failed. Rejecting the api call for /greetings
[2024-10-21 03:53:24,449 GMT| 2024-10-21 11:53:24,449717 | DBGHTTPSERVER| PID-2796| TID-3564| ERROR] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-startWSGIServer()-Line 5658- Timeout error occurred, exiting registration process exit code 7. Error - 3600 seconds
Traceback (most recent call last):
File "Http\HTTPServer.py", line 5656, in startWSGIServer
File "Http\HTTPServer.py", line 5503, in start_server
File "src\\gevent\\greenlet.py", line 1065, in gevent._gevent_cgreenlet.joinall
File "src\\gevent\\greenlet.py", line 1075, in gevent._gevent_cgreenlet.joinall
File "src\\gevent\_hub_primitives.py", line 250, in gevent._gevent_c_hub_primitives.wait_on_objects
File "src\\gevent\_hub_primitives.py", line 287, in gevent._gevent_c_hub_primitives.wait_on_objects
File "src\\gevent\_hub_primitives.py", line 185, in gevent._gevent_c_hub_primitives._WaitIterator.__next__
File "src\\gevent\_hub_primitives.py", line 176, in gevent._gevent_c_hub_primitives._WaitIterator.__next__
File "src\\gevent\_waiter.py", line 195, in gevent._gevent_c_waiter.MultipleWaiter.get
File "src\\gevent\_waiter.py", line 154, in gevent._gevent_c_waiter.Waiter.get
File "src\\gevent\_greenlet_primitives.py", line 61, in gevent._gevent_c_greenlet_primitives.SwitchOutGreenletWithLoop.switch
File "src\\gevent\_greenlet_primitives.py", line 61, in gevent._gevent_c_greenlet_primitives.SwitchOutGreenletWithLoop.switch
File "src\\gevent\_greenlet_primitives.py", line 65, in gevent._gevent_c_greenlet_primitives.SwitchOutGreenletWithLoop.switch
File "src\\gevent\_gevent_c_greenlet_primitives.pxd", line 35, in gevent._gevent_c_greenlet_primitives._greenlet_switch
gevent.timeout.Timeout: 3600 seconds
[2024-10-21 03:53:24,449 GMT| 2024-10-21 11:53:24,449717 | DBGHTTPSERVER| PID-2796| TID-3564| INFO] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-startWSGIServer()-Line 5660- Please follow the remediation steps mentioned below to resolve the problem :
1. Check if the host is approved/whitelisted on PowerProtect Data Manager server.
2. Alternatively, 'Auto Allow List' can be enabled on PowerProtect Data Manager server.
3. Ensure there is no connectivity issue from PowerProtect Data Manager server to agent system.
4. Restart the agent service and try again.
[2024-10-21 03:53:25,230 GMT| 2024-10-21 11:53:25,230570 | AGENTSVC_OP| PID-4320| TID-6672| ERROR] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\main.py-checkHttpServer()-Line 949- HTTPServer has stopped with exitcode 7.
[2024-10-21 03:53:25,230 GMT| 2024-10-21 11:53:25,230570 | AGENTSVC_OP| PID-4320| TID-6672| ERROR] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\main.py-checkHttpServer()-Line 951- Stopping the agentService

Cause

PowerProtect Data Manager File System 代理程式註冊失敗的根本原因是缺少反向 IP 查詢組態。執行 nslookup 以驗證 PowerProtect Data Manager 的名稱解析。它適用於 PowerProtect Data Manager 主機名稱,但不適用於反向 IP 查詢。 

主機名稱的 nslookup 輸出

IP 的 nslookup 輸出

PowerProtect Data Manager File System 使用者指南中記錄「必須設定名稱解析和反向 IP 查詢」 

PPDM 檔案系統使用者指南

Resolution

解決方案是在 DNS 伺服器上設定 PowerProtect Data Manager 的反向 IP 查詢。如果此時無法訪問 DNS 伺服器,請暫時修改用戶端上的主機檔。之後,UI 中的 「註冊狀態」應會自動變更為 「等待核准」。如果沒有,請在用戶端手動重新啟動 PowerProtect 代理程式服務。

用戶端的 PowerProtect 代理程式服務