Registrering af PowerProtect Data Manager File System Agent mislykkedes pga. problem med omvendt IP-opslagskonfiguration

Summary: Registrering af PowerProtect Data Manager File System-agent mislykkes på grund af problem med omvendt konfiguration af IP-opslag. Agentregistreringen mislykkes efter ny installation, når omvendt IP-opslag ikke er konfigureret. Du kan løse problemet ved at konfigurere omvendt IP-opslag på DNS-serveren eller ændre værtsfilen midlertidigt. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerProtect Data Manager File System Agent-registrering mislykkedes efter ny installation

Fra registreringsstatus for PowerProtect Data Manager-brugergrænsefladen> for agenter> vises Mislykkedes efter accept af certifikater.  

Skærmbillede af Application Agent med statussen

Skærmbillede af Application Agents med status

I C:\Program Files\DPSAPPS\AgentService\logs\OpAgentSvc-******.log, det viser nedenstående PPDM IpCheck validation failed for /greetings call.

[2024-10-21 03:53:05,643 GMT| 2024-10-21 11:53:05,643506 | DBGHTTPSERVER| PID-2796| TID-3564| INFO] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-checkIP()-Line 361- Could not fetch the host details for the address ppdm.local.com
[2024-10-21 03:53:05,643 GMT| 2024-10-21 11:53:05,643506 | DBGHTTPSERVER| PID-2796| TID-3564| INFO] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-checkIP()-Line 362- PPDM IpCheck validation failed. Rejecting the api call for /greetings
[2024-10-21 03:53:24,449 GMT| 2024-10-21 11:53:24,449717 | DBGHTTPSERVER| PID-2796| TID-3564| ERROR] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-startWSGIServer()-Line 5658- Timeout error occurred, exiting registration process exit code 7. Error - 3600 seconds
Traceback (most recent call last):
File "Http\HTTPServer.py", line 5656, in startWSGIServer
File "Http\HTTPServer.py", line 5503, in start_server
File "src\\gevent\\greenlet.py", line 1065, in gevent._gevent_cgreenlet.joinall
File "src\\gevent\\greenlet.py", line 1075, in gevent._gevent_cgreenlet.joinall
File "src\\gevent\_hub_primitives.py", line 250, in gevent._gevent_c_hub_primitives.wait_on_objects
File "src\\gevent\_hub_primitives.py", line 287, in gevent._gevent_c_hub_primitives.wait_on_objects
File "src\\gevent\_hub_primitives.py", line 185, in gevent._gevent_c_hub_primitives._WaitIterator.__next__
File "src\\gevent\_hub_primitives.py", line 176, in gevent._gevent_c_hub_primitives._WaitIterator.__next__
File "src\\gevent\_waiter.py", line 195, in gevent._gevent_c_waiter.MultipleWaiter.get
File "src\\gevent\_waiter.py", line 154, in gevent._gevent_c_waiter.Waiter.get
File "src\\gevent\_greenlet_primitives.py", line 61, in gevent._gevent_c_greenlet_primitives.SwitchOutGreenletWithLoop.switch
File "src\\gevent\_greenlet_primitives.py", line 61, in gevent._gevent_c_greenlet_primitives.SwitchOutGreenletWithLoop.switch
File "src\\gevent\_greenlet_primitives.py", line 65, in gevent._gevent_c_greenlet_primitives.SwitchOutGreenletWithLoop.switch
File "src\\gevent\_gevent_c_greenlet_primitives.pxd", line 35, in gevent._gevent_c_greenlet_primitives._greenlet_switch
gevent.timeout.Timeout: 3600 seconds
[2024-10-21 03:53:24,449 GMT| 2024-10-21 11:53:24,449717 | DBGHTTPSERVER| PID-2796| TID-3564| INFO] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\Http\HTTPServer.pyc-startWSGIServer()-Line 5660- Please follow the remediation steps mentioned below to resolve the problem :
1. Check if the host is approved/whitelisted on PowerProtect Data Manager server.
2. Alternatively, 'Auto Allow List' can be enabled on PowerProtect Data Manager server.
3. Ensure there is no connectivity issue from PowerProtect Data Manager server to agent system.
4. Restart the agent service and try again.
[2024-10-21 03:53:25,230 GMT| 2024-10-21 11:53:25,230570 | AGENTSVC_OP| PID-4320| TID-6672| ERROR] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\main.py-checkHttpServer()-Line 949- HTTPServer has stopped with exitcode 7.
[2024-10-21 03:53:25,230 GMT| 2024-10-21 11:53:25,230570 | AGENTSVC_OP| PID-4320| TID-6672| ERROR] C:\Program Files\DPSAPPS\AgentService\tmp_MEI50402\main.py-checkHttpServer()-Line 951- Stopping the agentService

Cause

Den grundlæggende årsag til registreringsfejl ved PowerProtect Data Manager File System-agenten tilskrives fraværet af omvendt IP-opslagskonfiguration. Kør nslookup på klientsiden for at kontrollere navnefortolkningen for PowerProtect Data Manager. Det fungerer for PowerProtect Data Manager-værtsnavnet, men ikke for omvendt IP-opslag. 

nslookup-output for værtsnavnet

nslookup-output for IP

Det er dokumenteret i brugervejledningen til PowerProtect Data Manager File System , at "Navnefortolkning og omvendt IP-opslag skal konfigureres" 

PPDM File System – Brugervejledning

Resolution

Løsningen er at konfigurere det omvendte IP-opslag i PowerProtect Data Manager på en DNS-server. Hvis DNS-serveren ikke er tilgængelig i øjeblikket, skal du midlertidigt ændre værtsfilen på klientsiden. Derefter skal registreringsstatus i brugergrænsefladen ændres til Afventer godkendelse automatisk. Hvis ikke, genstart PowerProtect Agent Service på klientsiden manuelt.

PowerProtect Agent Service på klientsiden

Affected Products

PowerProtect Data Manager
Article Properties
Article Number: 000239282
Article Type: Solution
Last Modified: 16 Dec 2024
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.