Dell e-SONiC: 4.4.0 and 4.4.1 - Incomplete running configuration in 'klish_show_running-configuration' file

Summary: The diagnostic information dumps created by 'show tech-support' command generates an incomplete 'klish_show_running-configuration' file.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The 'klish_show_running-configuration' file is generated and included within the diagnostic information dump created on execution of "show tech-support" command.
This file contains the configuration of the switch as displayed on execution of "show running-configuration" in the Management Framework CLI(MF-CLI).

In 4.4.0 and 4.4.1, the 'klish_show_running-configuration' file contains incomplete configuration. 

 

Cause

Software defect in Version 4.4.0 and 4.4.1

Resolution

Temporary Solution in affected versions

Use either of these commands to capture the MF-CLI running configuration:

show tech-support terminal
show running-configuration
 

Permanent Solution

Fix targeted in 4.5.0 release (Q2 2025). 

The release version and date are subject to change. Please refer the "Fixed Issues" section of release notes.