La mise à niveau de PowerFlex 4.x RCM sur le RG HCI échoue avec l’erreur : Échec de l’installation des VIB

Summary: La mise à niveau de RCM échoue lors de l’installation de VMware VIB, car les fichiers requis ne se trouvent plus dans le bundle RCM/IC.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

La mise à niveau de RCM échoue. La mise à niveau de RCM échoue au cours de la process_firmware_update :

Connectez-vous au pod thin-deployer et accédez à deployment.log du depoyment_ID/Job_ID
ERROR [2025-01-31T07:52:00.660421] 677128: service_deployment.rb:6081:in `process_firmware_update': Encountered an error during firmware update: RuntimeError: env --unset=RUBYOPT --unset=GEM_HOME --unset=RUBYLIB --unset=GEM_PATH --unset=BUNDLE_BIN_PATH RUBYLIB=/opt/service/lib:/opt/asm-deployer/lib:/opt/puppetlabs/puppet/lib:/opt/dependencies/dell-asm-util/lib PATH=/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin:/sbin:/bin:/opt/puppetlabs/puppet/bin:/opt/puppetlabs/bin puppet asm process_node --debug --trace --filename /opt/Dell/ASM/deployments/Job-2b551cc3-f546-4765-9eee-6416de02b254-0-0/resources/rackserver-cxjswf3.yaml --run_type apply --statedir /opt/Dell/ASM/deployments/Job-2b551cc3-f546-4765-9eee-6416de02b254-0-0/resources --always-override rackserver-cxjswf3 failed; output in /opt/Dell/ASM/deployments/Job-2b551cc3-f546-4765-9eee-6416de02b254-0-0/rackserver-abcdef3.out

ERROR [2025-01-31T07:56:00.831433] 677128: service_deployment.rb:7229:in `finalize_firmware_update': Failed to update the server!
INFO  [2025-01-31T07:56:00.831570] 677128: service_deployment.rb:7234:in `finalize_firmware_update': Firmware update status: Error
ERROR [2025-01-31T07:56:00.875669] 677128: service_deployment.rb:675:in `process': Firmware update failed for Job-2b551cc3-f546-4765-9eee-6416de02b254-0-0
ERROR [2025-01-31T07:56:00.875864] 677128: service_deployment.rb:676:in `process': ["/opt/asm-deployer/lib/asm/service_deployment.rb:7238:in `finalize_firmware_update'", "/opt/asm-deployer/lib/asm/service_deployment.rb:6095:in `process_firmware_update'", "/opt/asm-deployer/lib/asm/service_deployment.rb:526:in `process'", "/opt/asm-deployer/lib/asm.rb:385:in `block in process_deployment'", "org/jruby/RubyArray.java:2025:in `each_slice'", "/opt/asm-deployer/lib/asm.rb:366:in `block in process_deployment'", "/opt/dependencies/dell-asm-util/lib/asm/util.rb:22:in `block in execute_async'"]
INFO  [2025-01-31T07:56:00.876253] 677128: service_deployment.rb:678:in `process': Status: Error

À partir de l' .out de l’hôte ESXi, l’installation a échoué lors de l’installation des composants suivants :

/opt/Dell/ASM/deployments/<JOB_ID>/rackserver-service_tag.out<>
** /opt/Dell/ASM/deployments/Job-2b551cc3-f546-4765-9eee-6416de02b254-0-0/rackserver-abcdef3.out **
Error: Failed to install VIB for
["https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/INT_bootbank_i40en_2.5.2.0-1OEM.700.1.0.15843807.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6WY7ee0a$ [10[.]92[.]113[.]140]",
"https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/DEL_bootbank_dcism_5.3.0.0.3289-DEL.700.0.0.15843807.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6RyLpejW$ [10[.]92[.]113[.]140]",
"https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/VMware_locker_tools-light_12.2.6.22229486-22348808.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6SW0V3E0$ [10[.]92[.]113[.]140]",
"https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/INT_bootbank_ixgben_1.15.1.0-1OEM.700.1.0.15843807.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6dkiwDeX$ [10[.]92[.]113[.]140]",
"https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/INT_bootbank_i40en_2.5.2.0-1OEM.700.1.0.15843807.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6WY7ee0a$ [10[.]92[.]113[.]140]",
"https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/DEL_bootbank_dcism_5.3.0.0.3289-DEL.700.0.0.15843807.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6RyLpejW$ [10[.]92[.]113[.]140]",
"https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/INT_bootbank_ixgben_1.15.1.0-1OEM.700.1.0.15843807.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6dkiwDeX$ [10[.]92[.]113[.]140]"]: Error RbVmomi::Fault:VimEsxCLICLIFault: EsxCLI.CLIFault.summary

Error: Fault error message: [" [VibFormatError]", " ('<http.client.HTTPResponse object at 0xe3d7cbf310>', \"Not a valid ar file (magic=b'')\")", "  
filename = https://10.92.113.140:443/httpshare/download/8aaa801394ba0c920194ba1b53b00004/vibs70/VMware_locker_tools-light_12.2.6.22229486-22348808.vib__;!!LpKI!glu2235RWNPqShl_xs0gxErxlqUao3Xy5zb_dK_dKz6ireUNS8hD7XuE_BEHR6rXQHNZg5cpfSE5oolHSF-bVBu-6SW0V3E0$ [10[.]92[.]113[.]140]", " Please refer to the log file for more details."]

Debug: Host Maintenance mode = true

Warning: Host is in maintenance mode. Exiting Maintenance mode...

Error: Failed to install VIBs
/opt/puppetlabs/puppet/lib/ruby/vendor_ruby/puppet/util/errors.rb:157:in `fail'

Cause

Le problème provient du fait que le fichier VMware_locker_tools-light_12.2.6.22229486-22348808.VIB fait 0 octet dans le fichier RCM/IC, car DELL ne fournit plus ces fichiers. Toutefois, ils sont disponibles dans le dépôt de correctifs VMware, mais ont été ignorés pendant le processus de mise à jour. 

Resolution

L’une des solutions de contournement suivantes peut vous aider.

  1. Téléchargement du fichier VIB à l’aide de la mise à niveau d’un seul composant (SCU) :
    1. Extrayez le fichier VMware_locker_tools-light_12.2.6.22229486-22348808.VIB du dépôt de correctifs VMware.
    2. Activer la mise à niveau d’un seul composant (SCU).
      Connectez-vous à l’un des nœuds MVM et exécutez les opérations suivantes :
      kubectl patch hr asmmanager -p '{"spec":{"values":{"appConfig": {"modify_compliance":"true"}}}}' -n powerflex --type=merge
    3. Accédez à l’interface utilisateur de PFMP → Compliance Version → sélectionnez le bundle RCM → Software Bundle → sélectionnez « ESXi x.x Software Bundle », puis cliquez sur View → sélectionnez « VMware Tools VIB for Windows and Linux guest » dans la liste des composants et cliquez sur Modify.
      Téléchargez le fichier VMware_locker_tools-light_12.2.6.22229486-22348808.VIB et, sous « Nouvelle version de bundle », mentionnez la version suivante : 12.2.6.22229486-22348808. La version ici est la même que celle que vous voyez sous « Version de l’offre groupée ». Cliquez sur Continuer :
      Remarque : Vous voyez ce composant avec une balise « Modified ».

       

    4. Effectuez la mise à niveau RCM/IC.
       
  2. Installer manuellement le VIB VMware Tools :
    1. Installez manuellement le VIB extrait du package ZIP de mise à jour hors ligne téléchargé à partir de Broadcom :
      # esxcli software vib install -v /<path_to_the_depot>/VMware_locker_tools-light_12.2.6.22229486-22348808.vib
      Installation Result
         Message: Operation finished successfully.
         Reboot Required: false
         VIBs Installed: VMware_locker_tools-light_12.2.6.22229486-22348808
         VIBs Removed: VMware_locker_tools-light_12.3.5.22544099-22545121
         VIBs Skipped:
    2. Exécutez l’inventaire de l’hôte ESXi ci-dessus à partir de l’onglet « Ressources ».
    3. Vérifiez la conformité. Le VIB installé est marqué comme conforme et ignoré pendant le processus de mise à niveau.
    4. Effectuez la mise à niveau RCM/IC.
       
  3. Réessayez la mise à niveau du RCM.  La deuxième tentative devrait être couronnée de succès.

Additional Information

Versions affectées

PFMP 4.x

Problème résolu dans la version

PFMP 4.6.1 

Affected Products

PowerFlex rack RCM Software
Article Properties
Article Number: 000283204
Article Type: Solution
Last Modified: 02 Jun 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.