Dell Unity: Dell Unity-systemer må ikke tilsluttes via SAS-porten på DPE.

Summary: Hvis to (2) Dell Unity-systemer er forbundet ved hjælp af SAS-porten på Disk Processor Enclosure (DPE), kan data være utilgængelige og datatab forekomme.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

  • Hvis to (2) Dell Unity-systemer er forbundet via SAS-porten på DPE, mener den ene Unity DPE (Unity A), at den anden Unity DPE (Unity B) er en DAE. Unity A nulstiller disken på Unity B.

 

  • Unity B kan gå i panik og genstarte til servicetilstand med følgende: Rescue Reason: 0x0b00
Rescue reason for code 0x0b00 - There is a problem with the system software on this Storage Processor (BOOTFL). 
To attempt to correct this problem, first run Data Collection, and then try the following in order: 
Check all cables, reboot each SP, and reimage each Storage Processor (SP). 
If this does not resolve the issue, contact your service provider.
SP Service Hint Code: 0xFC0B0203 - Could not load mirror driver
Troubleshooting Steps Performed:

 

 

  •  Meddelelserne "Forkert plads" kan ses fra /EMC/C4Core/log/c4_safe_ktrace.log
14:11:08 service@FNXXXXXX spa:~/user# cat /EMC/C4Core/log/c4_safe_ktrace.log |grep -i 'wrong'
2025/07/31-23:20:43.860481 ~~~~ 7FB93D53D700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_0 Found: 0_1_0
2025/07/31-23:20:43.863842 ~~~~ 7FB93D53D700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_1 Found: 0_1_1
2025/07/31-23:20:43.866140 ~~~~ 7FB93D53D700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_2 Found: 0_1_2
2025/07/31-23:20:43.885914 ~~~~ 7FB93D53D700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_3 Found: 0_1_3
2025/07/31-23:21:44.088368 ~~~~ 7F01FE39E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_0 Found: 0_1_0
2025/07/31-23:21:44.091689 ~~~~ 7F01FE39E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_1 Found: 0_1_1
2025/07/31-23:21:44.093958 ~~~~ 7F01FE39E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_2 Found: 0_1_2
2025/07/31-23:21:44.113774 ~~~~ 7F01FE39E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_3 Found: 0_1_3
2025/07/31-23:22:50.870445 ~~~~ 7F9B11D9E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_0 Found: 0_1_0
2025/07/31-23:22:50.873760 ~~~~ 7F9B11D9E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_1 Found: 0_1_1
2025/07/31-23:22:50.875969 ~~~~ 7F9B11D9E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_2 Found: 0_1_2
2025/07/31-23:22:50.890182 ~~~~ 7F9B11D9E700 std:WARN SERV DBS 100C0 : MIR: MirrorReadMcrFruSignature: Wrong slot. Want: 0_0_3 Found: 0_1_3

 

 

  • Drev 0_0_0, 0_0_1, 0_0_2, 0_0_3 rapporterer som ugyldige drev i /EMC/C4Core/log/start_c4.log
14:11:08 service@FNXXXXXX spa:~/user# cat /EMC/C4Core/log/start_c4.log
2025-07-31 23:20:38.835 ===== reinit_if_needed =====
2025-07-31 23:20:39.200 ===== bringup_backend =====
2025-07-31 23:20:39.741 Loading mirror driver
2025-07-31 23:20:44.980 CM(sep)::start failed: Error: Command failed: -o execute -a 52609 – -o module_start -m sep: : NON_SPECIFIC at /EMC/csx/ubin64/csx_ctl.pl line 210.
2025-07-31 23:20:48.302 Shutting down backend SAS ports...
2025-07-31 23:20:52.354 Shut down backend SAS ports COMPLETED.
2025-07-31 23:21:02.119 MIR: system drive: 0_0_0 and 0_0_1 and 0_0_2 and 0_0_3 are invalid drives
2025-07-31 23:21:02.142 Three or more system drives {0_0_0,0_0_1,0_0_2,0_0_3}
are invalid.
2025-07-31 23:21:02.195 Bringing up the CSX infrastructure (timeout: 60, debug: 0)
2025-07-31 23:21:02.290 lst 0xb0000000:lsz 0x7d58000:ld 0xb7d57fff:hst 0x260000000:hsz 0xde0000000:hd0x103fffffff
2025-07-31 23:21:05.480 Starting the platform container.
2025-07-31 23:21:07.333 Bring up the GMS Server.
2025-07-31 23:21:07.410 Detected Memory Size (dmidecode): <65536>MB.
2025-07-31 23:21:08.293 Bolero_X1
2025-07-31 23:21:45.207 CM(sep)::start failed: Error: Command failed: -o execute -a 33971 – -o module_start -m sep: : NON_SPECIFIC at /EMC/csx/ubin64/csx_ctl.pl line 210.
2025-07-31 23:21:45.360 Increment the boot counter and go straight into Service Mode

Cause

Hvis to (2) Dell Unity-systemer er forbundet ved hjælp af SAS-porten på DPE, mener den ene Unity DPE (Unity A), at den anden Unity DPE (Unity B) er en DAE. Unity A nulstiller disken på Unity B.

Resolution

Tilslut ikke to (2) Dell Unity-systemer sammen ved hjælp af SAS-porten på DPE. 
Hvis de allerede er tilsluttet på denne måde, skal der foretages en fabriksinitialisering.
Der er intet ingeniørarbejde kan gøre for at gribe ind. 

 

 

 

 

Affected Products

Dell EMC Unity 300F, Dell EMC Unity 350F, Dell EMC Unity 400, Dell EMC Unity 400F, Dell EMC Unity 450F, Dell EMC Unity 500, Dell EMC Unity 500F, Dell EMC Unity 550F, Dell EMC Unity 600, Dell EMC Unity 600F

Products

Dell EMC Unity, Dell Unity 450F DC, Dell Unity 300, Dell Unity 300 DC, Dell Unity 350F DC, Dell EMC Unity XT 380, Dell EMC Unity XT 380F, Dell Unity 400 DC, Dell EMC Unity XT 480, Dell EMC Unity XT 480F, Dell EMC Unity 650F, Dell EMC Unity XT 680 , Dell EMC Unity XT 680F, Dell EMC Unity XT 880, Dell EMC Unity XT 880F, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Hybrid ...
Article Properties
Article Number: 000351789
Article Type: Solution
Last Modified: 19 Sep 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.