Avamar VM image backups fail with "No Proxy" error due to interrupted vCenter connection

Résumé: Avamar VM image backups fail with "No Proxy" error due to interrupted vCenter connection.

Cet article concerne Cet article ne concerne pas Cet article n’est associé à aucun produit spécifique. Toutes les versions du produit ne sont pas identifiées dans cet article.

Symptômes

The Activity Monitor in the Avamar UI shows 'No Proxy'.

The Activity Monitor in the Avamar GUI shows 'No Proxy'

On-demand VMware Image backup fails with the following:

Category: APPLICATION
Severity: PROCESS
Summary: Failed to initiate virtual machine backup or restore.
Event Information:
Event Code: 30931
Category: APPLICATION
Severity: PROCESS
Summary: Failed to initiate virtual machine backup or restore.

If a group backup request is initiated:
 

If a group backup request is initiated.
 

Cause

There was an interruption to the connection with vCenter.
This usually affects backups for all VM clients.

Résolution

  1. Check that Avamar can connect to the vCenter
  2. Go to Administration window and click on vCenter root domain
  3. Click on the vCenter client connection object and edit the client
  4. Verify the Avamar server IP or Hostname is valid
  5. Verify the vCenter user account that Avamar uses is valid
  6. Click OK to verify Avamar connect to vCenter
  7. Look at also restarting the MCS service on the Avamar server to clear any vCenter connection caching issues if the connection to vCenter was interrupted due to vCenter maintenance or network outage.

Informations supplémentaires

Produits concernés

Avamar

Produits

Avamar
Propriétés de l’article
Numéro d’article: 000033587
Type d’article: Solution
Dernière modification: 14 août 2023
Version:  3
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.