VCF on VxRail: NSX Upgrade From SDDC Manager Fails During Pre‑Check With Compute Manager or Transport Node Connectivity Errors
概要: NSX upgrades initiated from SDDC Manager may fail during the upgrade pre‑check with errors indicating that NSX is not properly connected to compute managers or transport nodes.
この記事は次に適用されます:
この記事は次には適用されません:
この記事は、特定の製品に関連付けられていません。
すべての製品パージョンがこの記事に記載されているわけではありません。
現象
During upgrade pre‑check in SDDC Manager, one or more of the following errors appear:
- "NSX audit not connected compute managers"
- "NSX audit not connected transport nodes"
In NSX Manager, affected transport nodes may show a degraded status.
原因
These errors occur when NSX components required for upgrade validation are not in a healthy connectivity state:
- The Compute Manager connection in NSX is DOWN.
- One or more Transport Nodes have connectivity failures or show a degraded operational state.
- Stale connectivity information may exist in SDDC Manager or vCenter
解決方法
Perform the following steps to remediate the issue:
- Resolve transport node connectivity issues in NSX, ensuring all impacted nodes return to a healthy state.
- Confirm that the Compute Manager connection is UP in NSX Manager.
- Restart the SDDC Manager appliance and vCenter Server.
- Rerun the SDDC Manager upgrade pre‑check.
- If failures continue, perform a rolling reboot of the NSX Manager cluster, rebooting the node hosting the VIP last.
その他の情報
For more information, see: While upgrading NSX from SDDC Manager, precheck fails with "NSX audit not connected compute managers" OR "NSX audit not connected transport nodes"
対象製品
VMWare Cloud on Dell EMC VxRail E560F, VMWare Cloud on Dell EMC VxRail E560N, VxRail E560 VCF, VxRail E560F VCF, VxRail E560N VCF, VxRail G560 VCF, VxRail G560F VCF, VxRail P570 VCF, VxRail P570F VCF, VxRail P580N VCF, VxRail S570 VCF
, VxRail V570 VCF, VxRail V570F VCF
...
文書のプロパティ
文書番号: 000440837
文書の種類: Solution
最終更新: 07 4月 2026
バージョン: 1
質問に対する他のDellユーザーからの回答を見つける
サポート サービス
お使いのデバイスがサポート サービスの対象かどうかを確認してください。