Dell Unity: Storage Processor Rescue Reason Error Code: 0x1b01
Sammendrag: Een Unity Storage Processor (SP) geeft een fout en gaat in de servicemodus met foutcode 0xb01, 6913 of 1:1678040.
Denne artikkelen gjelder for
Denne artikkelen gjelder ikke for
Denne artikkelen er ikke knyttet til noe bestemt produkt.
Det er ikke produktversjonene som identifiseres i denne artikkelen.
Symptomer
Een of beide storageprocessors kunnen zich in de servicemodus bevinden met de volgende reddingsreden:
======== Now executing basic state ========
* System Serial Number is: APM00172106812
* System Friendly Host Name is: (none)
* Current Software version: Unable to determine full software version.
* Unisphere IP address(es): 10.90.24.250 fe80::260:1600:47e0:2a26
* FIPS mode: Disabled
* Boot Mode: Rescue Mode
* Post Faults: 0x0000
* Backend Faults: 0x0000
* Boot Faults: 0x1b00
* Rescue Reason: 0x1b01
* Rescue reason for code 0x1b01 - There is a problem with the system software on this Storage Processor. To attempt to correct this problem, first run Data Collection, and then try the following in order: Check all cables, reboot each SP, and reimage each Storage Processor (SP). If this does not resolve the issue, contact your service provider.
De volgende extra foutcodes en berichten kunnen ook worden gegenereerd tijdens dit probleem:
ERROR" "1:1678040Storage Processor SP B has faulted and is in Service Mode with reason code 6913Storage Processor SP A has faulted and is in Service Mode with reason code 6913SERVICE_ERR_0x1b01
Årsak
De sep Dit probleem wordt meestal veroorzaakt door module in de veilige service. Controleer de volgende loglocaties om dit aan te tonen:.
/EMC/C4Core/log/start_c4.log:
Wed Sep 27 19:00:53 2017: start_c4.pl: *****************************************************
Wed Sep 27 19:00:53 2017: start_c4.pl: * Error Detected SP Degraded Mode after sep started.
Wed Sep 27 19:00:53 2017: start_c4.pl: * Incrementing SOFTWARE boot counter
Wed Sep 27 19:00:53 2017: start_c4.pl: * Driver rrchc code: 0x1b01
Wed Sep 27 19:00:53 2017: start_c4.pl: *****************************************************
/var/log/boot.out:
2017-09-29 18:36:31.598 ===== bringup_backend =====
2017-09-29 18:36:32.105 Loading mirror driver
2017-09-29 18:36:37.787 read degraded mode bit from nvram and check if sep is degraded
2017-09-29 18:36:37.996 MCR database degraded mode: 00000001
2017-09-29 18:36:38.332 1
2017-09-29 18:36:39.064 =================================================================
2017-09-29 18:36:39.068 === *** Going into service mode because of a fault *** ===
2017-09-29 18:36:39.072 =================================================================
2017-09-29 18:36:39.082 === When escalating to platform services, please make sure to ===
2017-09-29 18:36:39.086 === include the messages ABOVE this notice. You can ignore ===
2017-09-29 18:36:39.090 === any errors below. ===
2017-09-29 18:36:39.094 =================================================================Oppløsning
Neem contact op met de technische support van Dell of uw geautoriseerde servicevertegenwoordiger en vermeld deze ID van dit Dell Knowledge Base-artikel.
Berørte produkter
Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity HybridArtikkelegenskaper
Artikkelnummer: 000032808
Artikkeltype: Solution
Sist endret: 11 nov. 2025
Versjon: 4
Få svar på spørsmålene dine fra andre Dell-brukere
Støttetjenester
Sjekk om enheten din er dekket av støttetjenestene.