Dell EMC PowerEdge R7425 Installation and Service Manual

PSU specifications

The PowerEdge R7425 system supports up to two AC or DC power supply units (PSUs).

Table 1. PSU specifications

The table below are the specifications for 495 W, 750 W, 1100 W, 1600 W, 2000 W and 2400 W power supplies:

PSU Class Heat dissipation (maximum) Frequency Voltage High line 200v240 V Low line 100– 140 V DC Current
495 W AC Platinum 1908 BTU/hr 50/60 Hz 100–240 V AC, autoranging 495 W 495 W N/A 6.5 A–3 A
750 W AC Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC, autoranging 750 W 750 W N/A 10 A–5 A
750 W AC Titanium 2843 BTU/hr 50/60 Hz 200–240 V AC, autoranging 750 W N/A N/A 5 A
750 W Mixed Mode HVDC AC (for China only) Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC, autoranging 750 W 750 W N/A 10 A–5 A
750 W Mixed Mode HVDC DC(for China only) Platinum 2891 BTU/hr N/A 240 V DC, autoranging N/A N/A 750 W 4.5 A
750 W Mixed Mode AC Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC 750 W 750 W N/A 10 A-5 A
750 W Mixed Mode DC (for China only) Platinum 2891 BTU/hr N/A 240 V DC 750 W N/A 750 W 5 A
1100 W AC Platinum 4100 BTU/hr 50/60 Hz 100–240 V AC, autoranging 1100 W 1050 W N/A 12 A–6.5 A
1100 W DC N/A 4416 BTU/hr N/A –(48–60) V DC, autoranging N/A N/A 1100 W 32 A
1100 W Mixed Mode HVDC (for China and Japan only) Platinum 4100 BTU/hr 50/60 Hz 100–240 V AC, autoranging 1100 W 1050 W N/A 12 A–6.5 A
N/A 4100 BTU/hr N/A 200–380 V DC, autoranging N/A N/A 1100 W 6.4 A–3.2 A
1600 W AC Platinum 6000 BTU/hr 50/60 Hz 100–240 V AC, autoranging 1600 W 800 W N/A 10 A
2000 W AC Platinum 7500 BTU/hr 50/60 Hz 100–240 V AC, autoranging 2000 W 1000 W N/A 11.5 A
2400 W AC Platinum 9000 BTU/hr 50/60 Hz 100–240 V AC, autoranging 2400 W 1400 W N/A 16 A
NOTE Heat dissipation is calculated using the PSU wattage rating.
NOTE This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 240 V.
NOTE PSUs rated for 1100 W AC or 1100 W Mixed Mode HVDC and higher require high-line voltage (200–240 V AC) to supply their rated capacity.