Dell EMC PowerEdge R7425 Installation and Service Manual

Power supply unit indicator codes

AC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator and DC PSUs have an LED that serves as an indicator. The indicator shows whether power is present or a power fault has occurred.
Figure 1. AC PSU status indicator
This image shows AC PSU status indicator.
  1. AC PSU status indicator/handle
Table 1. AC PSU status indicator codesThis table describes the AC PSU status indicators and what condition is the PSU when the power indicator light is green, blinking amber, blinking amber, not illuminated, blinking green, and blinking green and turns off.
Power indicator codesCondition
GreenA valid power source is connected to the PSU and the PSU is operational.
Blinking amberIndicates a problem with the PSU.
Not illuminatedPower is not connected to the PSU.
Blinking greenWhen the firmware of the PSU is being updated, the PSU handle blinks green.
CAUTION Do not disconnect the power cord or unplug the PSU when updating firmware. If firmware update is interrupted, the PSUs do not function.
Blinking green and turns offWhen hot-plugging a PSU, the PSU handle blinks green five times at a rate of 4 Hz and turns off. This indicates a PSU mismatch with respect to efficiency, feature set, health status, or supported voltage.
CAUTION If two PSUs are installed, both the PSUs must have the same type of label; for example, Extended Power Performance (EPP) label. Mixing PSUs from previous generations of PowerEdge servers is not supported, even if the PSUs have the same power rating. This results in a PSU mismatch condition or failure to turn the system on.
CAUTION When correcting a PSU mismatch, replace only the PSU with the blinking indicator. Swapping the PSU to make a matched pair can result in an error condition and unexpected system shutdown. To change from a high output configuration to a low output configuration or vice versa, you must turn off the system.
CAUTION AC PSUs support both 240 V and 120 V input voltages with the exception of Titanium PSUs, which support only 240 V. When two identical PSUs receive different input voltages, they can output different wattages, and trigger a mismatch.
CAUTION If two PSUs are used, they must be of the same type and have the same maximum output power.
CAUTION Combining AC and DC PSUs is not supported and triggers a mismatch.
Figure 2. DC PSU status indicator
This image shows DC PSU status indicator.
  1. DC PSU status indicator
Table 2. DC PSU status indicator codesThis table describes the DC PSU status indicators and what condition is the PSU when the power indicator light is green, blinking amber, not illuminated, and blinking green.
Power indicator codesCondition
GreenA valid power source is connected to the PSU and the PSU is operational.
Blinking amberIndicates a problem with the PSU.
Not illuminatedPower is not connected to the PSU.
Blinking greenWhen hot-plugging a PSU, the PSU indicator blinks green. This indicates that there is a PSU mismatch with respect to efficiency, feature set, health status, or supported voltage.
CAUTION If two PSUs are installed, both the PSUs must have the same type of label; for example, Extended Power Performance (EPP) label. Mixing PSUs from previous generations of PowerEdge servers is not supported, even if the PSUs have the same power rating. This results in a PSU mismatch condition or failure to turn the system on.
CAUTION When correcting a PSU mismatch, replace only the PSU with the blinking indicator. Swapping the PSU to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to a Low Output configuration or vice versa, you must turn off the system.
CAUTION If two PSUs are used, they must be of the same type and have the same maximum output power.
CAUTION Combining AC and DC PSUs is not supported and triggers a mismatch.