Dell EMC PowerEdge R7425 Installation and Service Manual

Removing the left control panel

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the cooling fan assembly.
  4. Remove the air shroud.
    NOTE Ensure that you note the routing of the cables as you remove them from the system board. You must route the cables properly when you replace them to prevent the cables from being pinched or crimped.

Steps

  1. Lift the cable latch and disconnect the control panel cable from the system board connector.
  2. Using a Phillips #1 screwdriver, remove the screws that secure the control panel and cable tube to the system.
  3. Holding the control panel and cable tube by its sides, remove the control panel and cable tube away from the system.
    Figure 1. Removing the left control panel
    This image shows removing the left control panel.