Prerequisites for Rack Server, Cisco Nexus, and Compellent

The following table describes the prerequisites for the FCoE solution offered using Rack Server, Cisco Nexus and Compellent.

Table 1. Prerequisites for Rack Server, Cisco Nexus, and Compellent
Resource Prerequisites
Cisco Nexus

Following is the prerequisite for Cisco Nexus.

  • Enable required features.

    feature fcoe
                                                          feature npiv
                                                          feature lacp
                                                       
    • NOTE: On systems with Cisco Nexus B22 Fabric Extenders, internal ports 17-32 are not supported hence, certain network ports in some servers may not function when used with this device.
  • Create a new VSAN - instantiate it in the VSAN database.

    conf
                                                          vsan database
                                                          vsan <vsan id>
                                                       
  • Configure regular ethernet VLANs, and then the FCoE VLAN is created with an assignment to its respective VSAN.

    vlan <fcoe vlan>
                                                          fcoe vsan <vsan>
                                                       
  • Instantiate but do not configure the upstream port-channel (LAG) to the core /aggregation switch.

  • Instantiate but do not configure the downstream port-channel (LAG) to the IOA4.

  • Create the VFC interface to bind to the servers CNA FIP MAC address. This can be located in the CMC WWN table or the IDRAC page for the server.

    For Example

    interface vfc101
                                                          bind mac-address 5C:F9:DD:16:EF:07
                                                          no shutdown
                                                          
                                                          interface vfc102
                                                          bind mac-address 5C:F9:DD:16:EF:21
                                                          no shutdown
                                                       
  • Move back into the VSAN database and create entries for the new VFC just created and create entries for the FC port(s) that will be used.

    vsan database

    vsan 2 interface vfc101

    vsan 2 interface vfc102

    vsan 2 interface fc2/1

    vsan 2 interface fc2/2

    • NOTE: All the Compellent ports needs to part of the same VSAN.
Compellent

Create fault domain as per Compellent best practices.