chassisaction

Table 1. Chassisaction. The following table contains description, inputs, and options available in the chassisaction command.

Description

Runs a power action on the chassis or a switch.

To use this subcommand, you must have the Chassis Control Administrator privilege.

  • NOTE: For remote racadm, check the power status of the module using the getmodinfo command.

Synopsis

racadm chassisaction [-m <
                                                   module>] <
                                                   action>
                                                

Input

  • -m < module> — Module on which you want to carry out the action. Values are:
    • chassis — this is the default value, if -m is not specified.
    • switch-n, where n=1
  • < action> — Action that you want to run on the specified module. Values are:
    • powerdown — (Chassis only) Turns off the chassis.
    • powerup — (Chassis only) Turns on the chassis.
    • powercycle — Power cycles the module.
    • nongraceshutdown — (Chassis only) Non-gracefully turns off the chassis.
    • reset — Performs a hard reset of the module.

When < module > = switch, < action > must be powercycle or reset.

Output

None

Example

Perform a reset of switch-1:

racadm chassisaction -m switch-1 reset
Module power operation successful.