Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Chassis Management Controller Version 3.10 for PowerEdge VRTX RACADM CLI Guide

PDF

get psus

Table 1. Details of get psus. The following table provides the details of get psus attribute:

Description

Displays the status and attributes of the Power Supply Unit (PSU) in the storage enclosure that are connected to chassis

  • NOTE: To use this subcommand, you must have the CMC Login User privilege.

Synopsis

racadm raid get psus -o -p Status
                                                racadm raid get psus -o
                                             

Input

  • -o — The -o is used to display the fault-tolerant status of a enclosure.

Example

racadm raid get psus -o -p Status
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                
                                             
racadm raid get psus -o
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 0
                                                PartNumber                       = 0NFCG1A01
                                                PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 1
                                                PartNumber                       = 0NFCG1A01
                                                PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 0
                                                PartNumber                       = 0D1YWRA00
                                                PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
                                                Status                           = Ok
                                                State                            = Ready
                                                Name                             = PSU 1
                                                PartNumber                       = 0GV5NHA00
                                                
                                             