init

Table 1. Details of init. The following table provides the details of init attribute:
Description

Starts an initialization operation on the specified virtual drive.

Synopsis
racadm raid init:<VD FQDD> -speed {fast | full} {-current | -pending}
Input
  • –current <optional>: Performs the configuration right now.
    • NOTE: If this requires the system to reboot it will reboot then.
  • –pending: Save the configuration change for a later application. You can use a combination of the –pending and –current flags on multiple commands to reduce the possible number of system reboots.
  • –speed{fast | full}: Perform a fast or full (slow) initialization on the virtual drive.
Example
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed fast
                                                racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed full
                                                
                                             