Event ID — 2102

Description
Temperature exceeded the maximum failure threshold.
Severity
Critical / Failure / Error
Cause and Action
Cause: The physical disk enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot.

Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. See the physical disk enclosure documentation for more diagnostic information.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2091

SNMP Trap Numbers
1054