The following MIB tables provide information on the chassis power.
Table 1. DRsChassisIndex
Name drsChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only
Table 2. DRsPotentialPower
Name drsPotentialPower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2
Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on.
Syntax DellPowerReading
Access Read-only
Table 3. DRsIdlePower
Name drsIdlePower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3
Description Defines the power (in watts) required by the chassis infrastructure, along with the minimum power requirements for all systems currently turned on.
Syntax DellPowerReading
Access Read-only
Table 4. DRsMaxPowerSpecification
Name drsMaxPowerSpecification
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.4
Description Defines the power limit (in watts) at which server throttling takes place.
Syntax DellPowerReading
Access Read-only
Table 5. DRsPowerSurplus
Name drsPowerSurplus
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5
Description Defines the power surplus (in watts) remaining above the drsPotentialPower reading.
Syntax DellPowerReading
Access Read-only
Table 6. DRsKWhCumulative
Name drsKWhCumulative
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6
Description Defines the cumulative chassis power usage (in KWh) since last reset.
Syntax DellPowerReading
Access Read-only
Table 7. DRsKWhCumulativeTime
Name drsKWhCumulativeTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7
Description Defines the timestamp of the most recent chassis power accumulator reset.
Syntax DellTimestamp
Access Read-only
Table 8. DRsWattsPeakUsage
Name drsWattsPeakUsage
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8
Description Defines the chassis peak power usage (in watts) since last reset.
Syntax DellPowerReading
Access Read-only
Table 9. DRsWattsPeakTime
Name drsWattsPeakTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9
Description Defines the timestamp of the most recent chassis peak power usage.
Syntax DellTimestamp
Access Read-only
Table 10. DRsWattsMinUsage
Name drsWattsMinUsage
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10
Description Defines the chassis minimum power usage (in watts) since last reset.
Syntax DellPowerReading
Access Read-only
Table 11. DRsWattsMinTime
Name drsWattsMinTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11
Description Defines the time stamp of the most recent chassis minimum power usage.
Syntax DellPowerReading
Access Read-only
Table 12. DRsWattsResetTime
Name drsWattsResetTime
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.12
Description Defines the time stamp of the most recent reset of the chassis minimum/maximum watts readings.
Syntax DellTimestamp
Access Read-only
Table 13. DRsWattsReading
Name drsWattsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13
Description Defines the instantaneous chassis power usage (in watts).
Syntax DellPowerReading
Access Read-only
Table 14. DRsAmpsReading
Name drsAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14
Description Defines the instantaneous chassis current usage (in watts).
Syntax DellPowerReading
Access Read-only