Name | drsServerIndex |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.1 |
Description | Defines the index (one-based) of the associated CMC server. |
Syntax | DellCMCServerIndexRange |
Access | Read-only |
Name | drsServerMonitoringCapable |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.2 |
Description | Defines the monitoring capabilities, or the absence of a server in this location. |
Syntax | DellCMCServerCapable |
Access | Read-only |
Name | drsServerServiceTag |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.3 |
Description | Defines the Service Tag of the CMC server. |
Syntax | DellString |
Access | Read-only |
Name | drsServerSlotName |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.4 |
Description | Defines the slot name of the CMC server. |
Syntax | DellString |
Access | Read-only |
Name | drsServerSlotNumber |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.5 |
Description | Defines the chassis slot number of the CMC server. |
Syntax | DellString |
Access | Read-only |
Name | drsServerNodeID |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.6 |
Description | Defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. |
Syntax | DellString |
Access | Read-only |
Name | drsServerModel |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.7 |
Description | This attribute defines the Model of the CMC server. |
Syntax | DellString |
Access | Read-only |
Name | drsServerAssetTag |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.8 |
Description | This attribute defines the Asset Tag of the CMC server. |
Syntax | DellString |
Access | Read-only |
Name | drsServerNumStorageControllers |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.9 |
Description | This attribute defines the number of storage controllers on the storage sled. The value will be zero if this is not a storage sled. |
Syntax | INTEGER |
Access | Read-only |
Name | drsServerStorageMode |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.10 |
Description | This attribute defines the Storage Mode of the storage sled. |
Syntax | DellCMCServerStorageMode |
Access | Read-only |
Name | drsServerIntrusionState |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.11 |
Description | This attribute defines the Intrusion State of the CMC server if supported by the server. |
Syntax | DellCMCServerIntrusionState |
Access | Read-only |
Name | drsServerAssignedServerSlots |
Object ID | 1.3.6.1.4.1.674.10892.2.5.1.1.12 |
Description | This attribute defines the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or more server slots, the value will be a comma-separated list of one or more server slot names. If the storage sled is not assigned to a server slot, the value will be an empty string. If this is not a storage sled, the value will be N/A. |
Syntax | DellString |
Access | Read-only |