Issue ID | Functional area | Description | Workaround |
---|---|---|---|
157981 | An internal error occurred when running the DCIM_View class | When DCIM_View class is enumerated with any WS-Man client through the iSM
WMI Info feature on PowerEdge yx5x servers and iDRAC firmware 4.00.00.00 or later, the response is partial and unsuccessful with the following error code 5:
The specified class does not exist in the given namespace
The failure is because the DCIM_VFlashView class is deprecated starting with the iDRAC firmware version 4.00.00.00. |
Enumerate the explicit classes such as DCIM_CPUView, DCIM_FANView, and so on. |
87075 | A popup is displayed when uninstalling iSM | If the Firefox browser is opened when uninstalling the iSM, a popup is displayed. The popup notifies you that the Firefox browser must be closed before continuing the uninstallation procedure. | Close the Firefox browser, and click the Retry option to continue the uninstallation procedure. |
157981 | Running WMI MOF query on DCIM results with no data | When a Windows management instrumentation (WMI) MOF query is run on DCIM_View classes using iSM, no data is populated. | No action is required |
138538
146421 |
iSM communication with iDRAC switches from IPv6 to IPv4 | When iDRAC Service Module (iSM) is communicating with iDRAC over IPv6 protocol on a Microsoft Windows operating system, and if you perform an iDRAC Hard Reset operation or iDRAC firmware upgrade or downgrade, then the communication switches back to IPv4. | No action is required |
214241
219472 |
iSM command-line utility dcismcfg.exe on servers with Software RAID configuration | When the iSM command-line utility dcismcfg.exe is used to list the physical drives on Dell EMC PowerEdge servers with Software RAID configuration, the BayID property for SATA (HDD or SSD) drive is displayed incorrectly. | No action is required |
219358 | iSM operating system DUP installation | When iSM operating system DUP installation is completed, the following informational message is logged in the Windows Event Viewer: Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer. | The iDRAC Service Module installation is successful and no action is required. This message can be ignored. |
228003 | Software RAID feature | On PowerEdge yx3x servers configured with software RAID, the Software RAID feature may not be displayed in the iSM installshield wizard Custom Setup window. | Retry the installation of iDRAC Service Module on the server. |