iDRAC9 with Lifecycle Controller Version 3.19.19.19 Release Notes

PDF

Known issues — To be fixed in future releases

  1. Description

    Incorrect slot names are displayed in LC logs when NVMe Disks are installed in the system.

    Resolution
    When an NVMe disk is replaced in a system that has multiple slots in a bay, PR7 message is displayed with Bay <number>, where the <number> is actually the slot number. For example, in the following message, Slot number is 3 and Bay number is 2:
    [Date]   PR7   Dell NVMe PCIe SSD Configuration Data(Bay 3:Enclosure Internal 0-2)

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 79270

  2. Description

    Although the ProcAts attribute is not supported in BIOS, you may be able to create a configuration job using WSMan. However, the job fails and returns an error message. This attribute is not visible in any of the interfaces or WSMan enumeration.

    Resolution

    Do not use the ProcAts attribute because it is not supported in BIOS.

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 78968

  3. Description

    If the system has a direct-attached NVMe SSD configuration, a dummy storage NVMe controller named PCIe SSD in Slot 1 in Bay 1 (PC) is listed in SNMP Walk/Get.

    Resolution

    N/A

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 80884

  4. Description

    If you access the iDRAC web interface using Safari version older than 10, you cannot download any files from iDRAC.

    Resolution

    Use Safari version 10 or later, or use any other browser supported by this release.

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 82456

  5. Description

    Success event is logged in Lifecycle log when user tries to update NVDIMM with firmware that has a corrupted header.

    Resolution

    N/A

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 83367

  6. Description

    On a H830 controller, after you use auto-configuration to create more than 64 VDs and then try a reset-config operation, the pending delete action is applied only for the first 64 VDs.

    Resolution

    N/A

    Version/Systems affected: All system supported by this release.

    Dell tracking: 82424

  7. Description

    You cannot update the firmware for SEP Backplane using a catalog.

    Resolution

    For updating the firmware for SEP Backplane, use a single DUP.

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 79654

  8. Description

    If you upgrade to this version of iDRAC and then update the SEP backplane firmware to 4.23 on a system that has a SAS expander with an HBA330 controller, then the SEP update may fail.

    Resolution

    Perform a complete power cycle of the system and then retry the update. You can perform the power cycle either by completely turning off the system and turning it back on, or by using the racadm serveraction powercycle command. To avoid the power cycle, update the SEP backplane firmware before updating the iDRAC to this version.

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 87700

  9. Description

    If you have a network card with some 10G ports or faster and some 1G ports, Family Driver Version may not display the correct version or may display Unavailable.

    Resolution

    Use operating system tools or OMSA to view the driver version.

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 87441

  10. Description
    Using SCP import, you may be unable to configure user attributes when UserName attribute is at the end of the import file. The following error message is displayed in LCLog:
    RAC022: Unable to set values for User Password, IPMILan, IPMISerial or User Admin Privilege because the UserName is not configured.
    Resolution

    To configure user attributes, retry the SCP import operation. Alternatively, ensure that the UserName attribute appears first in User attributes list in the import file.

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 86360

  11. Description

    When NVMe mode is set to RAID, S140 controller's roll-up status is reported as OK (1) and even though the status is reported Unknown (0).

    Resolution

    N/A

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 90764

  12. Description

    On PowerEdge R940xa, after changing power-configuration settings in System Setup > iDRAC Settings, an error occurs while saving the changes. The PSU redundancy setting displayed are incorrect.

    Resolution

    To change power-configuration settings and PSU redundancy, use iDRAC web interface or RACADM.

    Version/Systems affected: PowerEdge R940xa

    Dell tracking: 95600

  13. Description

    If a catalog created using Dell Repository Manager (DRM) 3.x is used for updating firmware from LC UI, the update fails.

    Resolution

    Use a catalog created using DRM 2.x.

    Version/Systems affected: All systems supported by this release.

    Dell tracking: 97916

  14. Description

    When the backplane Signal A cable is unplugged, the System Event Logs indicates that the Signal B cable is unplugged. When the backplane Signal B cable is unplugged, the System Event Logs indicates that the Signal A cable is unplugged.

    Resolution

    N/A

    Version/Systems affected: PowerEdge R940xa

    Dell tracking: 97647


Rate this content