  1. While renaming a virtual disk (VD), using a . (period) is not allowed in the VD name.
  2. If your system has a PERC card configured in Enhanced HBA mode and you downgrade iDRAC to an older version, the SET commands for storage configuration may fail. To resolve the issue, ensure that a Collect System Inventory On Reboot (CSIOR) is performed after the downgrade. To perform a CSIOR, use the following methods:
    1. Completely turn off the system and then turn it on again.
    2. Ensure that CSIOR is enabled before turning off the system.
    3. Use the following RACADM command: racadm serveraction powercycle
  3. Few legacy drives do not support the SMART ID #245 "Remaining Rated Write Endurance". In such cases, iDRAC interfaces may display the "Remaining Rated Write Endurance" attribute as unavailable.
  4. If a M.2 SATA drive attached to BOSS-S2 controller is removed, performing a blink operation may not fail for the removed drive.