Table 1. Document revision historyTable listing the document revision history
Revision Date Description
A03 2022-04 Updated the E3200-ON Series switch information.
A02 2021-07 Correct the document version number.
A01 2021-02 Added Ukrainian to the output. Minor edits.
A00 2020-03 Initial release.

Support and documentation

  • For installation instructions, see the Dell PowerSwitch N3200-ON/E3200-ON Series Installation Guide at www.dell.com/support/.
  • To access the support site, go to www.dell.com/support/. To display information in your language, at the bottom of the page, select your country or region from the drop-down menu.

Information icon definitions:

WARNING The Warning icon signals information about hardware handling that could result in injury.
CAUTION The Caution icon signals information about situations that could result in equipment damage or loss of data.
NOTE The Note icon signals important operational information.

Warnings

WARNING To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment.
WARNING Only trained and qualified personnel can install this equipment. Read the safety instructions in your Safety, Environmental, and Regulatory.
WARNING This switch has multiple power cables. Disconnect all power cables before servicing.
WARNING This switch has optical transceivers, which comply with the limits of Class 1 laser radiation. When working with optical fibers, follow all warning labels and always wear eye protection.
WARNING When no cable is connected, visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports. Avoid exposure to laser radiation; do not stare into open apertures.
WARNING Never power up the switch if no fan module is installed. (Fixed-fan switches always have a fan module installed.)
WARNING Prevent exposure and contact with hazardous voltages. Do not attempt to operate this switch with the safety cover removed. To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC or DC Power Ports, use an external surge protection device (SPD) at the AC or DC input of the router.
WARNING Equipment that provides DC input to the DC port must be certified for CCC and meet the relevant standards.
WARNING This equipment must be grounded. Connect the power plug to a properly wired earth-ground socket outlet.

Cautions

CAUTION Operate the equipment at an ambient temperature not higher than 45°C (113°F).
CAUTION Stationary pluggable equipment Type-A used in a location with equipotential bonding, such as a telecommunication center, a dedicated computer room, or a restricted access area, must have installation instructions that require protective earth-ground connection verification by a skilled electrician.
Illustration of the earth-ground varification Caution in German.
CAUTION Illustration of the earth-ground verification Caution in German. Illustration of the power cord Caution with translations.

Illustration of the power cord Caution with translations.

Notes

NOTE If necessary, to upgrade your software or firmware images, go to the Drivers and Downloads page of your switch at www.dell.com/support/.
NOTE For proper ventilation, position the switch with a minimum of 12.7 cm (5 in) of clearance around the exhaust vents.
NOTE Install the switch into a rack or cabinet before installing any additional components such as cables or optics.
NOTE For the N3208PX-ON switch only: If you are using two external power adapters (EPAs) in a two-post front or center mount, you must have two-rack units space available in your rack. Install the switch in the bottom portion of the two-rack units and the EPA in the top portion above the switch.
NOTE Dell Technologies recommends you ground your switch. Use the switch in a common bond network (CBN). Grounding conductors must be made of copper. Copper conductors offer better conductivity and durability. Do not use aluminum conductors. Coat the one-hole lug with an anti-oxidant compound before crimping. Bring any unplated mating surfaces to a clean finish and coat with an anti-oxidant before mating.
NOTE For RoHS information, see Restricted Material Compliance.
NOTE This device is not intended for use in the direct field of view at visual display workplaces. To avoid incommoding reflections at visual display workplaces, this device must not be placed in the direct field of view.

Bemerkung: Dieses Gerät ist nicht für den Einsatz im direkten Sichtfeld am Bildschirmarbeitsplatz vorgesehen. Um störende Reflexionen am Bildschirmarbeitsplatz zu vermeiden, darf dieses Gerät nicht im direkten Sichtfeld platziert werden.

Table 2. N3208PX-ON and N3224T-ONTable listing N3208PX-ON and N3224T-ON information
Marketing model name N3208PX-ON N3224T-ON
Regulatory Model # (RMN)E30W E31W
Regulatory type # (RTN)E30W001 E31W002
BASE-T RJ45x 4

(1G) 802.3bt Type-4 (90 W) PoE

x 4

(5G) 802.3bt Type-4 (90 W) PoE

x 24

(1G)

10G SFP+x 2 x 4
25G SFP28
Stacking

x 2 QSFP28

(100G per port)
AC or (optional) DC PSU(1)One fixed AC PSU 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs
(Optional) External power adapter (EPA)x 2
(Optional) External power supply (EPS)
Fansx 1 x 3
Size

in (H x W X D)

mm (H x W x D)

Size excludes the PSU and fan tray handle

1.71 x 11 x 12.28

43.5 x 279.4 x 312

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU handle adds 1.18 in or 30 mm)

Weight(2)8.44 lbs/3.83 kg—240 W

13.75 lbs/6.24 kg

1 PSU:

1.75 lbs/0.79 kg—550 W

(1)Maximum number of PSUs available for the switch.

(2)Chassis weight with one PSU.

Table 3. N3224F-ON/E3224F-ON, N3224P-ON, and N3224PX-ONTable listing N3224F-ON/E3224F-ON, N3224PX-ON, and N3224P-ON information
Marketing model name N3224F-ON/E3224F-ON N3224P-ON N3224PX-ON
Regulatory Model # (RMN)E31W E32W E32W
Regulatory type # (RTN)E31W003/E31W006 E32W002 E32W001
BASE-T RJ45x 24

(1G) 802.3at PoE

x 24

(1G/2.5G/5G/10G) 802.3bt Type-4 (90 W) PoE

1G SFPx 24
10G SFP+x 4 x 4
25G SFP28x 4
Stacking

x 2 QSFP28

(100G per port)

x 2 QSFP28

(100G per port)

x 2 QSFP28

(100G per port)
AC or (optional) DC PSU(1)1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs
(Optional) External power adapter (EPA)
(Optional) External power supply (EPS)x 1
Fansx 3 x 3 x 3
Size

in (H x W X D)

mm (H x W x D)

Size excludes the PSU and fan tray handle

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU and fan tray handle adds 1.18 in or 30 mm)

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU and fan tray handle adds 1.18 in or 30 mm)

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU and fan tray handle adds 1.18 in or 30 mm)

Weight(2)

14.25 lbs/6.46 kg

1 PSU:

1.75 lbs/0.79 kg

15.6 lbs/7.08 kg

1 PSU:

2.0 lbs/0.90 kg—1050 W

16.0 lbs/7.26 kg

1 PSU:

2.0 lbs/0.90 kg—1600 W

(1)Maximum number of PSUs available for the switch.

(2)Chassis weight with one PSU.

Table 4. N3248X-ON, N3248TE-ON, N3248P-ON/E3248P-ON, and N3248PXE-ON/E3248PXE-ONTable listing N3248TE-ON, N3248P-ON/E3248P-ON, N3248X-ON, and N3248PXE-ON/E3248PXE-ON information
Marketing model name N3248TE-ON N3248P-ON/E3248P-ON N3248X-ON N3248PXE-ON/E3248PXE-ON
Regulatory Model # (RMN)E31W E32W E31W E32W
Regulatory type # (RTN)E31W005 E32W003/E32W006 E31W004 E32W004/E32W005
BASE-T RJ45x 48

(1G)

x 48

(1G) 802.3at (30 W) PoE

x 48

(1G/2.5G/5G/10G)

x 48

(1G/2.5G/5G/10G) 802.3bt Type-4 (90 W) PoE

10G SFP+x 4
25G SFP28x 4 x 4
10G SFP28x4
Stacking

x 2 QSFP28

(100G per port)

x 2 QSFP28

(100G per port)

x 2 QSFP28

(100G per port)

x 2 QSFP28

(100G per port)
AC or (optional) DC PSU(1)1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs
(Optional) External power adapter (EPA)
(Optional) External power supply (EPS)x 1 x 1
Fansx 3 x 3 x 3 x 3
Size

in (H x W X D)

mm (H x W x D)

Size excludes the PSU and fan tray handle

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU and fan tray handle adds 1.18 in or 30 mm)

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU and fan tray handle adds 1.18 in or 30 mm)

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU and fan tray handle adds 1.18 in or 30 mm)

1.71 x 17.09 x 15.75

43.5 x 434 x 400

(PSU and fan tray handle adds 1.18 in or 30 mm)

Weight(2)

15.4 lbs/6.99 kg

1 PSU:

1.75 lbs/0.79 kg—550 W

16.7 lbs/7.57 kg

1 PSU:

2.0 lbs/0.90 kg—1050 W

16.1/7.30 kg

1 PSU:

1.75 lbs/0.79 kg—550 W

17.6 lbs/7.98 kg

1 PSU:

2.0 lbs/0.90 kg—1600 W

(1)Maximum number of PSUs available for the switch.

(2)Chassis weight with one PSU.

Mexico-only NOM information

The following information is in compliance with the requirements of the official Mexican standards (NOM):
Table 5. NOMTable listing the Mexico-only NOM information.
Description Details
Exporter Dell Inc.

One Dell Way, Round Rock, TX 78682

Importer Dell México, S.A. de C.V.

Av. Javier Barros Sierra, no 540, Piso 10, Col. Lomas de Santa Fe

Delegación Álvaro Obregón, Ciudad de México. C.P. 01219

R.F.C: DME9204099R6

Ship to Dell México, S.A. de C.V.

Av. Javier Barros Sierra, no 540, Piso 10, Col. Lomas de Santa Fe

Delegación Álvaro Obregón, Ciudad de México. C.P. 01219

R.F.C: DME9204099R6

Supply voltage 100V–240 VAC
Frequency 50–60 Hz
Maximum steady state current consumption

See the Power consumption parameters table listed below.

N3200-ON/E3200-ON Series Specifications

Table 6. Environmental parametersTable listing environmental parameters.
Parameter Specifications
Operating temperature

0° to 45°C (32°F to 113°F) continuously

NOTE Reduce maximum temperature by 1°C/125 meters (1°F/228 feet) above 950 meters (3,117 ft).
Operating humidity

5% to 95% (RH), noncondensing

Storage temperature

–40°C to 70°C (–40°F to 149°F )

Storage humidity

5% to 95%, noncondensing

Maximum thermal output without PoE
  • N3208PX-ON: 49.48 W = 168.83 BTU/Hr
  • N3224T-ON: 95.58 W = 326.13 BTU/Hr
  • N3224F-ON/E3224F-ON: 122.08 W = 416.55 BTU/Hr
  • N3224P-ON: 100.74 W = 343.74 BTU/Hr
  • N3224PX-ON: 173.01 W = 590.33 BTU/Hr
  • N3248TE-ON: 102.3 W = 349.06 BTU/Hr
  • N3248X-ON: 300.06 W = 1023.85 BTU/Hr
  • N3248P-ON/E3248P-ON: 112.26 W = 383.05 BTU/Hr
  • N3248PXE-ON/E3248PXE-ON: 325.72 W = 1111.40 BTU/Hr
Maximum operational altitude

10,000 ft (3,048 m)

Maximum non-operational altitude 39,370 ft (12,000 meters)
Shock Dell Spec SV0115
Table 7. Power consumption parametersTable listing power consumption parameters.
Parameter Specifications
Input voltage

AC: 100 to 240 VAC 50/60 Hz

DC: –40 VDC to –60 VDC

Input current without PoE
  • N3208PX-ON: 1.12 Amps @ 110 VAC and 0.56 Amps @ 220 VAC
  • N3224T-ON: 2.08 Amps @ 110 VAC and 1.04 Amps @ 220 VAC
  • N3224F-ON/E3224F-ON: 2.32 Amps @ 110 VAC and 1.16 Amps @ 220 VAC
  • N3224P-ON: 2.26 Amps @ 110 VAC and 1.13 Amps @ 220 VAC
  • N3224PX-ON: 3.44 Amps @ 110 VAC and 1.72 Amps @ 220 VAC
  • N3248TE-ON: 2.22 AMps @ 110 VAC and 1.11 Amps @ 220 VAC
  • N3248P-ON/E3248P-ON: 2.4 Amps @ 110 VAC and 1.2 Amps @ 220 VAC
  • N3248X-ON: 4.9 Amps @ 110 VAC and 2.5 Amps @ 220 VAC
  • N3248PXE-ON/E3248PXE-ON: 5.44 Amps @ 110 VAC and 1.72 Amps @ 220 VAC
PSU configuration Main PSU
Maximum steady current consumption

7A@110VAC

3.5A@220VAC

Total PoE budget
NOTE To support a full-load PoE power budget, you must have external power adapters for the N3208PX-ON switch. For the N3224PX-ON, N3248P-ON/E3248P-ON, and N3248PXE-ON/E3248PXE-ON switches, use the EPS for full-load PoE redundancy.
  • N3208PX-ON: 720 W
  • N3224P-ON: 720 W
  • N3224PX-ON: 2160 W
  • N3248P-ON/E3248P-ON: 1440 W
  • N3248PXE-ON/E3248PXE-ON: 4320 W
PoE output per port
  • N3208PX-ON: 4x1000GBase-T Ports with 4 ports of 802.3bt Type-4 (90 W) PoE and 4x5GBase-T Ports with 4 ports of 802.3bt Type-4 (90 W) PoE
  • N3224P-ON: 24x1000Base-T Ports with 802.3at Type-2 (30 W) PoE
  • N3224PX-ON: 24x10GBase-T Ports with 802.3bt Type-4 (90 W) PoE
  • N3248P-ON/E3248P-ON: 48x1000Base-T Ports with 802.3at Type-2 (30 W) PoE
  • N3248PXE-ON/E3248PXE-ON: 48x10GBase-T MACSec Ports with 802.3bt Type-4 (90 W) PoE