Table 1. Known issues in Dell EMC OpenManage Plug-in for Nagios
Issue ID
Functional area
Description
Workaround or Resolution
JIT-92913
Device health status
Dell EMC Network Switch Physical Port Status service may get timed out in case high number of vlan/virtual ports are configured under monitored Dell EMC Network device.
Launch the respective switch console for the
Dell EMC Network Switch
host from the Nagios to view the health status of physical port.
JIT-93599
Platform
In
Dell EMC Server Controller Status
service, an extra instance will be shown only when
Dell EMC PowerEdge server
is been discovered using RedFish protocol and that device have SATA controller.
Launch the respective device console for the
Dell EMC PowerEdge server from Nagios to view the actual controller instance.
JIT-23682
Device status
Console launch happens using IPv4 address if Dell Chassis (M1000e, VRTX, and FX2/FX2s) is configured with both IPv4 and IPv6 and if chassis is discovered using IPv6 address.
Not applicable.
JIT-100978
Device status
Status of all services are shown as unknown if the device is discovered using the FQDN and the IP of the device gets changed after discovery.
Rediscover the device with the same FQDN.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\