Managed servers must have an Integrated Dell Remote Access Controller
(iDRAC) 6, 7, or 8. It is recommended to use the latest version firmware.
Power Distribution Unit (PDU) and Uninterruptible Power Supply
(UPS) devices must comply with the Management Information Base (MIB)
the vendor provides through SNMP interface.
Devices must provide exclusive access for Power Center because
the policies set on the devices from other management software affect
the Power Center power control function.
The Baseboard Management Controller (BMC) user, through which
Power Center communicates with devices, must be a local user account
whose roles include Administrator. The device must be configured to
allow the Administrator to use at least one of the cipher suite levels
0–3, and enable the IPMI over LAN setting.
The WSman user, through which Power Center communicates with the
chassis, must be a local user with the Administrator role. The chassis
must be configured to enable the Web Server service.