Virtual disk fails rebuild using a dedicated hot spare

Issue:
A virtual disk fails during rebuild while using a dedicated hot spare.
Probable Cause:
One or more disks in the virtual disks fails or is disconnected while the rebuild is in progress.
Corrective Action:
No action is required. The dedicated hot spare is in hot spare state and converted to global hot spare if there is any other virtual disk that is supported, otherwise the dedicated hot spare reverts to Ready state and the virtual drive is in Failed state.