Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge RAID Controller 9 User’s Guide H330, H730, and H830

Smart error detected on a physical disk in a redundant virtual disk

Issue:
A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective Action:
Perform the following steps:
  1. Back up your data.
  2. Force the physical disk offline.
    NOTE:If a hot spare is present, the rebuild starts with the hot spare after the disk is forced offline.
  3. Replace the disk with a new physical disk of equal or higher capacity.
  4. Perform the Replace Member operation.
    NOTE:The Replace Member operation allows you to copy data from a source physical disk of a virtual disk to a target physical disk that is not a part of the virtual disk. For more information about the Replace Member feature, see the topic Using Replace Member And Revertible Hot Spares.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\