Dell PowerEdge RAID Controller 9 User’s Guide H330, H730, and H830

Automatic replace member with predicted failure

A Replace Member operation can occur when there is a SMART predictive failure reporting on a physical disk in a virtual disk. The automatic Replace Member is initiated when the first SMART error occurs on a physical disk that is part of a virtual disk. The target disk needs to be a hot spare that qualifies as a rebuild disk. The physical disk with the SMART error is marked as failed only after the successful completion of the Replace Member. This prevents the array from reaching degraded state.

If an automatic Replace Member occurs using a source disk that was originally a hot spare (that was used in a rebuild), and a new disk added for the Replace Member operation as the target disk, the hot spare reverts to the hot spare state after a successful Replace Member operation.

NOTE:To enable the automatic Replace Member, use the Dell OpenManage storage management application. For information on manual Replace Member, see Replacing An Online Physical Disks.