Processor
Processor type One or two Intel Xeon processor E5-2600 product family
Expansion Bus  
Bus type PCI Express Generation 3 and 2
Expansion slots:  
    (Slot 1) One full-height, full-length x8 link
    (Slot 2) One full-height, full-length x16 link
    (Slot 3) One full-height, full-length, x4 link
  • NOTE: Slot 3 is PCI Express Generation 2 only.
    (Slot 4) One full-height, full-length x16 link
   
  • NOTE: Both the processors must be installed to use slots 5 through 7.
    (Slot 5) One full-height, full-length x16 link
    (Slot 6) One full-height, full-length x8 link
    (Slot 7) One full-height, full-length x16 link
Memory  
Architecture 800 MT/s, 1066 MT/s, 1333 MT/s, or 1600 MT/s DDR3 registered, unbuffered or load-reduced Error Correcting Code (ECC) DIMMs
  Support for advanced ECC or memory optimized operation
Memory module sockets Twenty-four 240-pin
Memory module capacities  
  LRDIMMs 32 GB quad-ranked
  RDIMMs 2 GB, 4 GB, 8 GB, or 32 GB single-, dual-, or quad-ranked

16 GB single- or dual-ranked

  UDIMMs 2 GB, 4 GB, or 8 GB
Minimum RAM 2 GB with a single processor
  4 GB with two processors
Maximum RAM  
  LRDIMMs Up to 768 GB
  RDIMMs Up to 512 GB
  UDIMMs Up to 128 GB
Drives  
Hard drives  
  Four–hard-drive systems Up to four 3.5 inch, internal, hot-swappable SSD, SATA, or SATA hard drives

hard-drive slots 0 through 3 (hard-drive slots 4 through 7 do not support any hard drives and are installed with hard-drive blanks)

  Eight–hard-drive systems Up to eight 3.5 inch, internal, hot-swappable SAS, SATA, or Nearline SAS hard drives

hard-drive slots 0 through 7

  Twelve–hard-drive systems Up to twelve 3.5 inch, internal, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives

hard-drive slots 0 through 11

  Eight plus four-hard drive systems Up to eight 3.5 inch, internal, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives, and four Dell PowerEdge Express Flash devices (PCIe SSDs)
  Sixteen–hard-drive systems Up to sixteen 2.5 inch, internal, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives

hard-drive slots 0 through 7 and 8 through 15

Up to sixteen 2.5 inch, internal, hot-swappable SAS, SATA hard drives and four SATA SSDs

  Sixteen plus four hard-drive systems Up to sixteen 2.5 inch, internal, hot-swappable SAS, SATA, or SATA SSD hard drives plus four PCIe SSDs

hard-drive slots 0 through 3, 0 through 7, and 8 through 15

  Thirty two–hard-drive systems with a single PERC card Up to thirty two 2.5 inch, internal, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives

hard-drive slots 0 through 7, 8 through 15, 16 through 23, and 24 through 31

  Thirty two–hard-drive systems with double PERC card Up to thirty two 2.5 inch, internal, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives

hard-drive slots 0 through 7, 8 through 15, 0 through 7, and 8 through 15

Optical drive One optional SATA DVD-ROM drive or DVD+/-RW drive
  • NOTE: DVD devices are data only.
Connectors  
Back  
  NIC Two 10/100/1000 Mbps
  Serial 9-pin, DTE, 16550-compatible
  USB Six Hi-Speed USB Host
  Video 15-pin VGA
Front  
  USB Two Hi-Speed USB Host
  Video 15-pin VGA
  • NOTE: The front VGA port is available only with the rack configuration.
  External vFlash memory card One vFlash memory card slot
Internal  
  USB One 4-pin, USB 2.0-compliant
  Internal Dual SD Module Two optional flash memory card slots with the internal SD module
  • NOTE: One card slot is dedicated for redundancy.
Video  
Video type Integrated Matrox G200
Video memory 16 MB shared
Expanded Operating Temperature  
  • NOTE: When operating in the expanded temperature range, system performance may be impacted.
  • NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.
  < 10% of annual operating hours 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.
  • NOTE: Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to 5 °C or up to 40 °C for a maximum of 10% of its annual operating hours.

For temperatures between 35 °C and 40 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 175 m above 950 m (1 °F per 319 ft).

  < 1% of annual operating hours –5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.
  • NOTE: Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to –5 °C or up to 45 °C for a maximum of 1% of its annual operating hours.

For temperatures between 40 °C and 45 °C, de-rate maximum allowable dry bulb temperature by 1 °C per 125 m above 950 m (1 °F per 228 ft).

  Expanded Operating Temperature Restrictions
  • You must have six fans configured on your system.
  • Do not perform a cold startup below 5 °C.
  • The operating temperature specified is for a maximum altitude of 3048 m ( 10,000 ft).
  • Express Flash is not supported.
  • GPU is not supported.
  • LRDIMM is not supported.
  • 130 W 4 Core processor, 135 W processors, and 150 W processors are not supported.
  • Non-redundant power supplies are not supported.
  • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
Environmental  
  • NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Temperature  
  Maximum Temperature Gradient (Operating and Storage) 20 °C/h (36 °F/h)
  Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F)
Temperature (Continuous Operation)
  Temperature Ranges (for altitude less than 950 m or 3117 ft) 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment.
  Humidity Percentage Range 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point.
Relative Humidity  
  Storage 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times.
Maximum Vibration  
  Operating 0.26 G rms at 5 Hz to 350 Hz (all operation orientations).
  Storage 1.87 G rms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum Shock  
  Operating One shock pulse in the positive z axis of 31 G for 2.6 ms in all operational orientations.
  Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Maximum Altitude  
  Operating

3048 m ( 10,000 ft).

  Storage 12,000 m (39,370 ft).
Operating Altitude De-rating
  Up to 35 °C (95 °F) Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft).
  35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft).
  40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft).
Particulate Contamination
  • NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer.
  Air Filtration
  • NOTE: Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
  • NOTE: Air entering the data center must have MERV11 or MERV13 filtration.
  Conductive Dust
  • NOTE: Applies to data center and non-data center environments.
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
  Corrosive Dust
  • NOTE: Applies to data center and non-data center environments.
  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
Gaseous Contamination
  • NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
  Copper Coupon Corrosion Rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
  Silver Coupon Corrosion Rate <200 Å/month as defined by AHSRAE TC9.9.