Dell PowerVault MD 34XX/38XX Series Storage Arrays CLI Guide

PDF

Reset Storage Array SAS PHY Baseline

Description

This command resets the SAS physical layer (SAS PHY) baseline for all devices except physical disks, and removes the list of errors from the . csv file. The . csv file is generated by running the save storageArray SASPHYCounts command.

  • NOTE: The reset storageArray SASPHYBaseline command clears error counts for all devices except the physical disks. After running this command, the . csv file continues to list the DrivePHY errors. All other errors are deleted from the . csv file.

Syntax

reset storageArray SASPHYBaseline

Parameters

None.