The following high severity issues remain unresolved in this release:

Table 1. Known issues in Storage Manager 2020 R1.2Storage Manager 2020 R1.2 known issues
Issue Functional area Description Workaround/Resolution
DSM-26371 Cross-platform replication Storage Manager might incorrectly display the progress of a cross-platform replication as 100% after pausing a cross-platform replication at 50% and then restarting the lead controller on the PS Group. Resume the replication.
DSM-20458 Cross-platform replication Storage Manager does not prevent the user from deleting a port that is used in replication. Deleting the port from the fault domain breaks the replication. Contact technical support to restart the replication if a port has been deleted.
DSM-19844 Cross-platform replication The Modify Space Settings option is displayed for PS Groups when cross-platform replication is not configured. None
DSM-19667 Cross-platform replication Storage Manager does not immediately display restore points for unplanned disaster recovery activations. Refresh the Replications view or relaunch the Storage Manager Client.
DSM-17016 Cross-platform replication Storage Manager displays replication schedules for replications from PS Group to PS Group. Storage Manager does not manage replications between PS Groups. None
DSM-16737 Cross-platform replication Storage Manager does not allow you to set up a replication from a Storage Center to a PS Group when creating a volume on the Storage Center. Set up the replication to the PS Group using the Replicate Volume wizard.
DSM-15904 Cross-platform replication Storage Manager displays an incorrect error after setting up a replication from a Storage Center to a PS Group with insufficient delegated space. Modify the amount of delegated space on the PS Group to accommodate the replication.
DSM-14648 Cross-platform replication Storage Manager does not automatically map a volume to the server after activating disaster recovery on a replication from a PS Group to a Storage Center. Manually map the volume to the server.
88549 Cross-platform replication When replicating more than 16 volumes from a PS Series group to a Storage Center, Storage Manager displays replications in a Waiting state as Down. Do not replicate more than 16 volumes at a time.
DSM-28532 Miscellaneous After changing the Chargeback department of a volume that has the same index as a volume on a different Storage Center, Storage Manager might not show that the volume changed Chargeback departments. Storage Manager might also change the Chargeback department of the volume with the same index on the other Storage Center. Perform a Copy/Mirror/Migrate to a new volume. This problem does not occur if the new volume does not share an index with a different volume on another system.
DSM-27414 Miscellaneous When changing the BMC interface configuration mode from static to DHCP, the IP addresses remain set up in static mode. If you change the configuration mode from DHCP to static, and modify only the IPv4 address, Storage Manager changes the netmask and gateway IP addresses to invalid values. After modifying the configuration mode, ensure that the IP addresses are correct.
DSM-16593 Miscellaneous Applying SNMP setting to other Storage Centers without SNMP enabled fails without displaying an error. Enable SNMP on the Storage Center before applying any settings.
DSM-23693 PS Series Group Management Storage Manager displays a PS Series group as inactive after a controller failover on the PS Series group. Remove the PS Series group from Storage Manager and then add it back.
DSM-13871 PS Series Group Management When an online Thin Import of a boot volume is performed from a PS Series group to a Storage Center, the server is unable to boot from the volume after mapping it to the server. Online Thin Import is not supported with boot volumes.
DSM-9294 Replications and Live Volumes When creating multiple replications or Live Volumes simultaneously, correcting a configuration error and resuming the process can create duplicate replications or Live Volumes. If a creation operation fails, do not use the wizard to correct the configuration error and continue. Instead, exit and restart the wizard, and then resume creating replications or Live Volumes from the point of failure.
ENHTKR-90 Replications and Live Volumes When importing a volume, Storage Manager does not allow you to select 0 as the LUN number. None
DSM-30033 Storage Management Creating a server using the Create Server from VMware vSphere or vCenter wizard fails if the host contains adapters that are not VMware software iSCSI adapters. Create the server manually using the Create Server dialog box.
DSM-28354 Storage Management Storage Manager might not display information for some Hyper-V virtual machine volumes that are monitored with the Server Agent in the Servers view. View information for those volumes in the Storage view.
DSM-28295 Storage Management After reinstalling the Server Agent, it might fail to register the server with Storage Manager. Register the server in the Storage Manager Client.
DSM-20038 Storage Management During initial setup of Storage Center, the Discover and Configure Storage Centers wizard might close while updating the Storage Center. You cannot open the Discover and Configure Storage Centers wizard to complete the setup until the controllers finish restarting. Wait for the controllers to power on, reconnect to the Storage Center, and then launch the Discover and Configure Uninitialized Storage Centers wizard.
DSM-13200 Storage Management Storage Manager does not delete a Snapshot Profile until a refresh if the Snapshot Profile was deleted without the recycle bin and was assigned to a volume. Refresh the Storage Manager Client.
DSM-11762 Storage Management When creating a volume using the Server Agent, Storage Manager might show a warning that the label contains illegal characters if another volume on the Storage Center contains unsupported characters. Remove the unsupported characters from the label of the volume.
DSM-9428 Storage Management Creating a server cluster using the Create Server from vSphere or vCenter wizard creates server cluster Storage Center objects for each node in the server cluster. None
DSM-9390 Storage Management Creating an RDM for a VM hosted on an ESXi or vSphere host maps the volume to the server in the cluster instead of the cluster object. Manually promote the volume to the ESXi server cluster mappings, then rescan for hosts on the vCenter server.
DSM-47431 Storage Manager Client The Discover and Configure Uninitialized Storage Centers wizard does not open when the Discover and Configure Uninitialized Storage Centers clicking the link on the initial launch screen of a Storage Manager Client that it is installed on Windows Server 2012 R2.
NOTE The initial launch screen has a white background.
  • Open the wizard by clicking the Discover and Configure Uninitialized Storage Centers link on the second launch screen of the Storage Manager Client.
    NOTE The second login screen has a black background.
  • Open the wizard by clicking the Discover and Configure Uninitialized Storage Centers link after connecting the Storage Manager Client to a Data Collector.
DSM-47433 Storage Manager Client If the Storage Manager Client is not connected to a Data Collector, using the Discover and Configure Uninitialized Storage Centers wizard to discover uninitialized Storage Centers might result in an Administrator rights error message. This issue occurs even when you are logged in as a user with Administrator rights. Connect the Storage Manager Client to a Data Collector and then use the Discover and Configure Uninitialized Storage Centers wizard to discover uninitialized Storage Centers.
DSM-47392 Storage Manager Client The Create Server dialog box, Create Server Cluster dialog box, and Preferences tab in the Edit Storage Center Settings dialog box might not display properly in the Linux version of the Storage Manager Client. Use Unisphere Central to perform the operations.
DSM-36674 Storage Manager Client When an SCv3000 Series storage system contains both an iSCSI I/O card and a mezzanine card, the deployment wizard only shows the cabling diagram for the iSCSI I/O card. None
DSM-36577 Storage Manager Client When the Storage Manager Client and Data Collector are in different time zones, the timestamps are different. Do not set a time zone value for the Data Collector UTC setting.
DSM-36253 Storage Manager Client When creating a server, the Operating System information dialog box shows the Maximum Path Count as zero instead of 32 or unlimited. None
DSM-31931 Storage Manager Client If a system has multiple disk folders, the Storage Alert Threshold field on the Summary tab displays the data for the last disk folder in the list. View the threshold data in the Thresholds Alerts view.
DSM-28859 Storage Manager Client The welcome screen for the Storage Manager Client on Red Hat Linux Enterprise is blank when the Color Depth of the Windows Remote Desktop Connection is set to Highest Quality (32 bit). Set the Color Depth of the Windows Remote Desktop Connection to True Color (24 bit) or High Color (16 bit).
DSM-26168 Storage Manager Client The Storage Manager Client displays the delete option when volumes and volume folders are selected. However, the Storage Manager Client does not support deleting volumes and volume folders in one action. Delete volumes and volume folders separately.
DSM-14009 Storage Manager Client Refreshing the Storage Manager Client does not clear the red dot indicator from the Storage Center node. Restart the Storage Manager Client.
DSM-9577 Storage Manager Client The front-end SAS card for an SCv2000 series controller does not provide WWN information to ESXi host. Record the SAS WWN information before installing it in an ESXi hosts.
DSM-9477 Storage Manager Client The Storage Manager Client might report that a restart in sequence has completed even though the restart has not completed. Verify that the restart completes before continuing.
DSM-7908 Storage Manager Client The I/O Usage report that is exported in XML format does not display all the information for the French output when opened in a web browser. Open the report using a text editor such as Notepad.
SCOS-12316 Storage Manager Client The Storage Manager Client displays multi-VLAN tagging options for I/O cards that do not support multi-VLAN tagging. Do not enable multi-VLAN tagging on QLogic cards that do not support it.
DSM-41119 Storage Manager Data Collector Database errors might occur if a Data Collector uses an internal flat file database and manages a Storage Center with multiple disk folders. Use an external database instead of an internal flat file database for the Data Collector.
CAUTION Internal flat file databases are not recommended for Data Collectors in production environments.
DSM-37868 Storage Manager Data Collector If a Storage Center with an expired password disconnects from the Data Collector, the Storage Center cannot be reconnected to the Data Collector. Change the password on the Storage Center by directly connecting to it using the Storage Manager Client or Unisphere.
DSM-42715 Storage Replication Adapter (SRA) SRM generates the following error message when two separate volumes use the same LUN number mapped to different hosts and are both are configured for replication:
Duplicate LUN 'X' for initiatorGroup
None
DSM-43060 Storage Replication Adapter (SRA) Site Recovery Manager (SRM) might generate the following error message when a recovery or reprotect operation is performed:
Unable to switch the site preference to the recovery site for the device.
SRA command 'prepareFailover' failed for device.
  1. Stop the Remote Data Collector.
  2. Restart the Primary Data Collector.
  3. Start the Remote Data Collector.
DSM-28137 Storage Replication Adapter (SRA) SRM planned failovers with Live Volumes fail when vMotion is not enabled in the environment. Enable vMotion. The Storage Replication Adapter (SRA) with Stretched Storage and Live Volumes requires vMotion.
DSM-18751 Storage Replication Adapter (SRA) The installation wizard for the Storage Replication Adapter (SRA) allows you to begin updating from an older version of SRA. Updating from previous versions of the SRA is not supported. Uninstall the previous version of the Storage Replication Adapter (SRA), and then install the new version.
DSM-47422 SupportAssist and Updating On new installations of Storage Manager Data Collector 2020 R1, an "Unable to connect to external website using proxy settings specified" error might occur when a proxy server is configured for SupportAssist. Uninstall Storage Manager Data Collector 2020 R1, install Storage Manager Data Collector 2019 R1, configure the proxy server, and update to Storage Manager Data Collector 2020 R1.
DSM-36088 SupportAssist and Updating Occasionally, when starting a non-service affecting update for a Storage Center through the Data Collector, Storage Manager loses connectivity with the Storage Center. The system automatically resolves the connectivity issue.
DSM-45590 Unisphere Customers might experience issues displaying graphs on the Performance tab in Unisphere Central. Use the Storage Manager Client connected to the Data Collector to display Performance graphs.
DSM-42195 Unisphere Exporting monitoring data to PDF for multiple Storage Centers might cause Unisphere Central to become nonresponsive until the export is completed. Use the Storage Manager Client connected to the Data Collector to export monitoring data to PDF.
DSM-39691 Unisphere The following error message might be displayed in the Unisphere web interface while performing the initial setup and configuration of a Storage Center:
The connection to the server has been lost
Refresh the browser to reload the Unisphere web page and continue the Storage Center initial setup and configuration.
DSM-38756 Unisphere When a Storage Center contains over 50 expansion enclosures, the Unisphere Hardware view displays a server error. Use the Storage Manager Client to view hardware information for large systems.
DSM-36355 Unisphere Some views in Unisphere might fail to load and display an error message for storage systems with many expansion enclosures. Use the Storage Manager Client to view information for storage systems with many expansion enclosures.
DSM-36253 Unisphere When creating a server, the Operating System information dialog box shows the Maximum Path Count as zero instead of 32 or unlimited. None
DSM-35454 Unisphere When an action is applied to more than 128 objects, the action may fail. None
DSM-34120 Unisphere Unable to create an empty disk folder on a hot spare system that has available disks. None
DSM-33384 Unisphere Using Internet Explorer to view large numbers LDAP users might cause the user interface to become unresponsive. Use a different web browser such as Chrome or Firefox.
DSM-32169 Unisphere The Performance view may be cut off when using Internet Explorer. Use a different web browser such as Chrome or Firefox.
DSM-16373 Unisphere Unisphere Central does not show the progress of a Data Collector data source change. Use the Storage Manager Client to change the data source of a Data Collector.
DSM-35011 User Management Cannot configure an OpenLDAP directory server for a Storage Center using Storage Manager or Unisphere. None
DSM-24536 User Management Attempting to use the characters < or > in User and User Group settings might result in an error. Do no use these characters in User and User Group settings.
DSM-15445 User Management Adding Storage Manager to Active Directory fails when you use the distinguished name (DN) of a user. Use the user principal name (UPN) to add Storage Manager to an Active Directory realm.
DSM-12329 User Management When a user is unlocked, the status of the user might not change immediately. Refresh the Storage Manager Client.
DSM-44104 VMware Frequently migrating virtual machines from one vVol datastore to another vVol datastore might result in orphaned volumes. None
DSM-16656 VMware If you select the Auto Manage Virtual Machines On Storage Centers option during the initial Dell Storage Manager registration of a vCenter server, all the discovered ESXi hosts along with their VMs are rendered within the Servers tree of the Storage panel. If any of these VMs are later deleted from vCenter, they remain in the Dell Storage Manager view. To remove these deleted VMs from Dell Storage Manager, right-click the VM and then delete it.
DSM-16248 VMware On rare occasions, selecting Update information in the Dell Storage Manager Server view results in the error java.net.SocketException: Unexpected end of file from server. Despite the vCenter appearing to be online and able to accept connections, the vCenter must be restarted to reestablish proper connectivity between Dell Storage Manager and vCenter.
DSM-15879 VMware The Host Setup wizard for VMware does not allow you to select an HBA on an ESXi host that contains adapters that are not VMware software iSCSI adapters. When establishing an integrated environment with Dell Storage Manager and VMware, there are multiple options available for you to import the VMware known inventory into Dell Storage Manager for enhanced management benefits. You can choose to add hosts individually, or by creating and registering from a vCenter server. Although the option exists in the Storage tab to create from vCenter server, the preferred and more reliable method is to use the Dell Storage Manager Server tab. Select the Server folder and then Register Server > Add VMware vCenter Server. Then, select Auto Manage Storage Centers to populate the Storage Center.
DSM-15803 VMware On rare occasions, when a vVol VM is migrated from one vVol datastore to another, a config or data vVol might become orphaned on the original datastore. This vVol counts against the total vVol scale and takes up unnecessary space. Contact technical support to handle the removal of the VM.
DSM-15302 VMware If you attempt to delete a datastore which is populated (not empty) using the Storage Manager Client, an error occurs. A false indicator of connectivity is represented by a red X on the vCenter server. Click the Update Information button in the top-level menu.
DSM-15000 VMware A vVol VM snapshot with quiesce guest file-system option fails. Install the VMware Tools without the VSS feature. For more information, see VMware Knowledge Base article number 2069952.
DSM-14997 VMware When using sDRS with vVols, vCenter incorrectly recommends migrating the VM when both vVols are on the same Storage Center. Review the recommendations from vCenter before taking action.
DSM-14891 VMware A fast clone VM shows history with the VM from which it was created. Hence the data vVols of this clone VM inherit the settings of the data vVols of the original VM. This shared history also has the following consequences:
  • Changing the Data Reduction profiles for a storage container might cause future fast cloned VMs to be created with mismatched Data Reduction profiles for the config and data vVols.
  • If a user applies a VM Storage Policy to the original VM, the same changes apply to the data vVols of the fast clone VM and conversely.
None
DSM-14806 VMware Migrate or Clone operations on virtual machines with snapshots might fail if not enough space is available in the vVol datastore hosting the VM. The temporary space overhead that is required by these operations depends on the size of the individual disks and the number of snapshots of the VM.
  1. Check if the vVol datastore (storage container) is nearing capacity.
  2. Increase the size of the vVol datastore to sufficiently accommodate the overhead and then retry the operation.
DSM-14570 VMware If you attempt to register the VASA Provider with a DSM user with Reporter privilege, it fails as expected. However, an incorrect error message Username or password is incorrect is reported. The correct error should be user with Reporter privilege is not allowed to register VASA provider. Ignore the error message, and register VASA Provider with a Storage Manager Data Collector user with Administrator privilege.
DSM-14149 VMware If you try to apply a new VM Storage Policy while Storage vMotion of a VM is in progress, the compliance status of the VM goes to Out of Date. Reapply the new storage policy after Storage vMotion has completed.
DSM-13316 VMware After increasing the storage container size in Dell Storage Manager, the vCenter user interface shows the datastore with the new size. However, it still displays an error for insufficient space when it tries to create a VM. Unmount and then remount the datastore.
DSM-13042 VMware On rare occasions, if vVol operations (cloning and snapshots) are occurring on multiple VMs concurrently using scripting that results in the eventual deletion of vVols, an attempt to delete a vVol VM might result in vVols not being deleted. This scenario results in inefficient space consumption and reduction in total vVols available for future use. Removal of the vVols is not a user-level corrective option. Contact technical support for assistance. Avoid running concurrent vVol operations using scripting. Instead, script either sequential operations or operations with interjected delays.
DSM-12732 VMware It is possible to create a storage container, and a subsequent vVol datastore using it, of a logical size that exceeds the physical capacity of the storage array. The capacity values that are displayed in vCenter for an oversubscribing container reflect the correct free or total physical capacity values instead of the logical storage container values. None
DSM-11417 VMware When high availability (HA) is configured, vVols are migrated from the active host to the standby host when management network access to the active host is lost. This situation is similar to VMFS, and is the expected behavior. However, if only the data network goes down, VMFS datastores migrate to the standby host, but vVols do not fail over. VMCP is not supported with vVols. No workarounds are available when the data network goes down, but the management network stays up. However, if the management network to the active host goes down, failover is triggered, regardless of the state of the data network .

Rate this content