The following
conditions must be fulfilled before you enable NUMA FRM:
ESXi 5.5 U2 must be deployed on any of the following Dell PowerEdge
systems:
M630
R730
R730XD
R630
FC630
The BIOS version on your system must be 1.2.1 or later for Dell’s
13th generation of PowerEdge systems that supports VMware ESXi 5.5
U2 or later under ESXi 5.5.x..
The memory modules must be populated on the memory channels to
support Mirror Mode. For more information,
see your system Owner’s Manual at dell.com/poweredgemanuals.
You need vSphere Enterprise or Enterprise Plus licensing to enable
the VMware Reliable Memory technology.
Complete the
following steps to enable FRM on your system:
Turn on your system.
The Dell logo is displayed.
Press F2 to open the System Setup page
Use the up- and down-arrow keys to select the System BIOS option, and then select Memory
Settings .
Select NUMA Fault Resilient Mode for Memory Operating Mode.
CAUTION: Dell recommends that you do not modify other settings
unless you are familiar with the settings. Modifying settings could
cause your system to fail to boot or function properly.
Press Enter, and follow the on-screen procedure to save
these changes.
Restart your system.
NOTE: No further
configuration changes are required for ESXi to make use of the reliable
memory region.