Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Changing the Sampling Rate

The sflow sample-rate command, when issued in CONFIGURATION mode, changes the default sampling rate.

By default, the sampling rate of an interface is set to the same value as the current global default sampling rate. If the value entered is not a correct power of 2, the command generates an error message with the previous and next power-of-2 value. Select one of these two numbers and re-enter the command. (For more information on values in power-of-2, refer to Sub-Sampling.)

To change the sampling rate either globally or on an interface, use the following command.

Change the global or interface sampling rate. CONFIGURATION mode or INTERFACE mode [no] sflow sample-rate sample-rate sample-rate : The range is from 256 to 8388608 for the C-Series and S-Series. The range is from 2 to 8388608 for the E-Series. The rate must be entered in factors of 2 (for example, 4096 or 8192).