Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Classifying Layer 2 Traffic on Layer 3 Interfaces

To process Layer 3 packets that contain Dot1p — (IEEE 802.1p) Packet classification (Layer 2 headers), configure VLAN tags on a physical Layer 3 interface (that is configured with an IP address and is not associated with any VLAN). You can also configure a VLAN subinterface over a physical underlying interface and classify packets using the dot1p value.

To apply an input policy map to Layer 3 physical interfaces, use the service-policy input policy-name layer 2 command in Interface Configuration mode.

To apply a Layer 2 policy on Layer 3 interfaces, perform the following:

  1. Configure an interface with an IP address or a VLAN subinterface CONFIGURATION mode Dell(conf)# int fo 0/0 INTERFACE mode Dell(conf-if-fo-0/0)# ip address 90.1.1.1/16
  2. Configure the Layer 2 policy with Layer 2 (Dot1p or source MAC-based) classification rules. CONFIGURATION mode Dell(conf)# policy-map-input l2p layer2
  3. Apply the Layer 2 policy on the Layer 3 interface. INTERFACE mode Dell(conf-if-fo-0/0)# service-policy input l2p layer2

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"