To select and apply the updates, from the Available
System Updates table, select the check box beside the component that has the firmware you want to update. After you
select the catalog ID, details of the firmware selected are displayed
in the following format:
Release Date: YYYY-MM-DD
Source: USB Drive or CD or DVD (<device type>): \<firmware file name in .exe format>
By default, Lifecycle Controller selects the
components for which the current updates or higher version of the current installed version is available.
Click Apply. The system may restart after
the update process is complete. When applying more than one update,
the system may restart between the updates and launch back to Lifecycle
Controller, and continue with the other selected updates.
NOTE:The system
does not restart after updating the operating system driver pack and
hardware diagnostics.
NOTE:While using Lifecycle
Controller to update the Power Supply Unit (PSU) firmware, the system
turns off after the first task. It takes a couple of minutes to update
the PSU firmware, and then automatically turns on the server.