Dell Command | Configure Version 4.0 Command Line Interface Reference Guide
Completion code
The following table displays the completion code of an update operation performed by BIOS in the recent shutdown or reboot operation.
| Code | Description |
|---|---|
| 0000h | The update was completed successfully. |
| 0001h | The image failed one or more consistency checks. |
| 0002h | The BIOS could not access the flash-memory device. |
| 0003h | The flash-memory device was not ready when an erase was attempted. |
| 0004h | Flash programming is currently disabled on the system, or the voltage is low. |
| 0005h | A battery must be installed for the operation to complete. |
| 0006h | A fully-charged battery must be present for the operation to complete. |
| 0007h | An external power adapter must be connected for the operation to complete. |
| 0008h | The 12V required to program the flash-memory could not be set. |
| 0009h | The 12V required to program the flash-memory could not be removed. |
| 000Ah | A flash-memory failure occurred during a block-erase operation. |
| 000Bh | A general failure occurred during the flash programming. |
| 000Ch | A data miscompare error occurred during the flash programming. |
| 000Dh | The image could not be found in memory or the header could not be located. |
| 000Eh | Reserved for future assignment via this specification. |
| FFFFh | No update operation has been performed on the system. |