Skip to main content
PowerEdge C6420 image

PowerEdge C6420

PowerEdge C6420

Articles

Select a category and then related component(s) to find articles about specific hardware and software.

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 507 shown
507 out of 507 shown

Correctable and uncorrectable memory errors on PowerEdge Server with DDR4 and changes to troubleshooting steps
Updated:  September 11, 2026 ID: 000053203

Information about how Troubleshooting and Diagnose PowerEdge servers and CPU issues.
Updated:  September 10, 2026 ID: 000179752

This article shows how to do network card testing using the Support Live Image (SLI).
Updated:  September 10, 2026 ID: 000120458

This article identifies which Operating System (OS) files the iDRAC Service Module (iSM) replicates the Lifecycle Controller (LC) logs to.
Updated:  September 10, 2026 ID: 000064204

This article provides information about how to create a bootable USB drive from and OS ISO file for manual installation.
Updated:  September 10, 2026 ID: 000334285

This document highlights minimum, recommended, and latest code versions for Dell Technologies PowerEdge products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  September 10, 2026 ID: 000227230

The Dell Nautilus Firmware Update Utility is flexible and simple to use as it contains all the latest, relevant firmware updates for hard drives in your Dell server.
Updated:  September 10, 2026 ID: 000141811

Dell OS and Applications Solutions on Dell TechCenter - Project Sputnik, Microsoft Windows, Red Hat Linux, SUSE, Ubuntu, and more
Updated:  September 10, 2026 ID: 000145895

How to Identify the physical slot number in iDRAC based off the device name in vSphere/VSAN.
Updated:  September 09, 2026 ID: 000179543

Firmware updates using the iDRAC or LifeCycle Controller does not work on any Emulex 8 Gb fiber channel adapter.
Updated:  September 09, 2026 ID: 000144615

This article describes how to reenable the Lifecycle Controller (LCC) when it goes into recovery mode.
Updated:  September 09, 2026 ID: 000136186

Micron 5x00 Series SSDs may experience read/write performance degradation after reaching approximately 65,535 power-on hours (POH), which equates to roughly 7.5 years of operation. This issue affects performance only and does not result in data loss or drive failure.
Updated:  September 09, 2026 ID: 000464492

This article provides information about how to update your system's firmware from the Lifecycle Controller on Dell servers.
Updated:  September 09, 2026 ID: 000128133

BIOS downgrading is blocked for certain memory configurations to prevent a system stop caused by a microcode issue in older versions.
Updated:  September 09, 2026 ID: 000067023

This article shows How To determine why a virtual machine powered off or rebooted by reviewing log files and host details to identify guest shutdowns, user or API requests, HA resets or system faults.
Updated:  September 07, 2026 ID: 000205778

Learn how to create and export a SupportAssist Collection using iDRAC9 and iDRAC10 on Dell devices. Resolve technical issues with this step-by-step guide.
Updated:  September 04, 2026 ID: 000126308

This article explains how to perform a driver or firmware update directly from the operating system (OS) using a Dell Update Packages (DUP).
Updated:  September 04, 2026 ID: 000130467

Dell iDRAC9 and iDRAC10 remediations for a Command Injection security vulnerability that could be exploited by malicious users to compromise the affected system.
Updated:  September 03, 2026 ID: 000504998

If the LifeCycle Controller (LCC) is enabled but it is missing in the menu during the POST, it is possible that you must import the iDRAC license to enable it again.
Updated:  September 03, 2026 ID: 000205309

This article explains how to find supported memory configuration for your PowerEdge server.
Updated:  September 02, 2026 ID: 000135681

There are special considerations for GPU firmware updates outlined in this article.
Updated:  September 02, 2026 ID: 000291566

To replace a CMOS battery, remove the air shroud, disconnect and remove any expansion cards, locate the battery socket, and carefully pry out the CMOS battery. After installing a new CMOS battery, you must reinstall the expansion cards, install the air shroud, and restore the BIOS settings, ensuring the battery is operating properly and the correct data and time are set in the System Setup.
Updated:  September 02, 2026 ID: 000234357

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  September 02, 2026 ID: 000227912

This article describes how to find the iDRAC's current MAC address.
Updated:  September 02, 2026 ID: 000226214

Most PowerEdge servers and other products that leverage a PowerEdge server hardware have an embedded Integrated Dell Remote Access Controller. This article helps to quickly identify the iDRAC version.
Updated:  September 02, 2026 ID: 000177885

This article describes the "Easy Restore", which is a built-in storage component that maintains critical configuration information.
Updated:  September 02, 2026 ID: 000142633

This article explains how to use the Import Server License feature to import an iDRAC license from the Lifecycle Controller UI.
Updated:  September 02, 2026 ID: 000139682

Frequently Asked Questions (FAQ) about Physical Drives replacement in RAID Server and MD Arrays
Updated:  September 02, 2026 ID: 000139367

This article provides information about how to delete a virtual disk using the Device Settings menu on a PowerEdge server. If your PowerEdge server is running the UEFI mode as a boot mode, the RAID BIOS is not displayed.
Updated:  September 02, 2026 ID: 000136465

This article provides information about how to disable C-States and C1E on a PowerEdge Server.
Updated:  September 02, 2026 ID: 000135039