Articles
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 742 shown
742 out of 742 shown
This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: December 22, 2025
ID: 000205512
This article explains the cause and resolution of alerts related to the Baseboard Management Controller (BMC), also known as iDRAC on Dell PowerEdge-based platforms. The BMC is an embedded controller that monitors system health parameters such as temperature, fan speeds, power status, and voltage. When the BMC becomes unresponsive or fails, the Data Domain system generates an alert.
Updated: December 16, 2025
ID: 000203937
A NetWorker VMware Protection (NVP) Virtual Machine (VM) File Level Restore (FLR) fails to mount. Instant Access restore may also fail. The error logging returns that the vProxy failed to log in in to the Data Domain because the REST service on the Data Domain is disabled.
Updated: January 09, 2026
ID: 000397486
Cloud tier cleaning will not start a quota limit that the ECS admin controls has been reached
Updated: January 09, 2026
ID: 000367373
Failover bonding on Data Domain relies on link state. If a NIC fails without link change, failover will not occur, causing possible connectivity loss if no alternate interface exists.
Updated: January 09, 2026
ID: 000184654
This article provides frequently asked questions and solutions for a DDOS upgrade.
Updated: January 09, 2026
ID: 000081005
NetBackup restores failing due to a changed SIZE_DATA_BUFFERS_DISK to 1048576 (1MB) (or a value that is similar)
Updated: January 09, 2026
ID: 000198367
To provide the air-gap feature of Cyber Recovery (CR), it ups and downs replication interfaces on Data Domain. There is a timing issue, with bonded interface configuration, that results in link status down being reported.
Updated: January 09, 2026
ID: 000202629
Interface groups can be used to control the interfaces used for DD Boost MFR, to direct the replication connection over a specific network, and to use multiple network interfaces with high bandwidth and reliability for failover conditions. All protection
system IP types are supported—IPv4 or IPv6, Alias IP/VLAN IP, and LACP/failover aggregation.
Updated: January 09, 2026
ID: 000204051
Introduced in DDOS 7.5 and DDMC in 7.11, multifactor authentication adds an extra layer of security on the protection system. It requires the security officer and system administrator to enter an RSA SecurID passcode before certain destructive commands or configuration changes are allowed.
The Multifactor Authentication panel allows the user to configure, enable, and disable multifactor authentication.
Updated: January 09, 2026
ID: 000204191
Data Domain - /data/col1/backup MTree is the default MTree that has been created for backward compatibility to older DDOS versions and is not allowed to be deleted.
Updated: January 09, 2026
ID: 000200177
When using failover bonding, the standby interface has many dropped packets. This is expected since the standby interface is not active.
Updated: January 09, 2026
ID: 000200178
DDOS can diagnose authentication issues for Active Directory from within the DD System Manager interface.
Updated: January 09, 2026
ID: 000204197
This article explains how to create a DD Boost Protocol Storage Unit using either UI or CLI.
Updated: January 09, 2026
ID: 000204264
About interface groups: This feature lets you combine multiple Ethernet links into a group and register only one interface on the protection system with the backup application. The DD Boost Library negotiates with the system to obtain the best interface to send data. Load balancing provides higher physical throughput to the system.
Configuring an interface group creates a private network within the system, consisted of the IP addresses designated as a group. Clients are assigned to a single group, and the group interface uses load balancing to improve data transfer performance and increase reliability.
Updated: January 09, 2026
ID: 000204276
This issue is not caused by Data Mover itself. It occurs due to NFSv4 identity-mapping behavior on the client side.
Updated: January 08, 2026
ID: 000091436
This article describes the purpose of the Domain Name System (DNS) alert "Unable to communicate with configured DNS" on Data Domain operating system 5.5 and later.
Updated: January 08, 2026
ID: 000071415
This KB article describes when to use if group and when to use link aggregation control protocol bonding and when to use both simultaneously.
Updated: January 08, 2026
ID: 000121645
The Data Domain system backup operations rely on the Data Domain system file system. In case the file system is disabled or failed, all backup operations to the device will be halted.
This document lists steps on how to verify if the file system is working properly.
Updated: January 08, 2026
ID: 000043648
Error while destroying the ddboost association
Updated: January 07, 2026
ID: 000047851
MTREE replication shows incorrect bytes_remaining during initialization.
Updated: January 07, 2026
ID: 000042735
NetBackup Air Replication error "DDErrNo = 5034 (the user has insufficient privilege)."
Updated: January 07, 2026
ID: 000028938
DDBOOST_USER' does not have sufficient access rights is seen from NetWorker side even though DDBOOST user is working fine from DD side and also if you tried to change PW, assign new Storage Unit it encounters same error "DDBOOST_USER' does not have sufficient access rights"
Updated: January 07, 2026
ID: 000263089
On DDOS versions 7.10, 7.13, 8.0, 8.1, 8.2, 8.3.0.x Data Domain (DD) systems with drive firmware updates enabled may encounter unexpected, false disk failures. Specifically, two devices per Disk Group (DG) can transition to a failed state due to a RAID module reference count issue in the kernel. This can lead to system instability and potential data availability risks.
Updated: January 07, 2026
ID: 000331892
This article explains the supported compression algorithms on Data Domain systems and provides guidance on selecting the appropriate compression type based on performance and data characteristics.
Updated: January 07, 2026
ID: 000028820
This article addresses potential communication issues between PowerProtect Data Manager (error code ADS0005) and Data Domain during discovery jobs, focusing on MTU mismatches.
Updated: January 07, 2026
ID: 000382377
During a DDOS upgrade on DD3300 systems, the precheck may fail with a blocking error indicating that the DellPTA Agent is not running. This article outlines the steps to resolve the issue by verifying and restarting the necessary services on the ESXi host.
Updated: January 07, 2026
ID: 000381511
The client-side session timeout resets communication with Data Domain causing backup failures.
Updated: January 07, 2026
ID: 000226173
filesys clean status command might show the cleaning finished, however filesys clean watch will show the cleaning still in progress
Updated: January 07, 2026
ID: 000206083
This article explains how disk capacity is calculated for the active tier in Data Domain systems and how RAID 6 overhead reduces usable capacity. It does not apply to other storage tiers.
Updated: January 07, 2026
ID: 000010749