To ensure optimal performance and stability for your Dell system, be aware of the latest updates available for the drivers and firmware. There are several systems to do this as explained in the article below.
Updated: November 26, 2025
ID: 000127716
Dell guidance to mitigate risk and resolution for the side-channel analysis vulnerabilities (also known as L1 Terminal Fault or L1TF) for servers, storage, and networking products. For specific information about affected platforms and next steps to apply the updates, see this guide.
Updated: August 25, 2025
ID: 000137307
A Storage Processor fails to start after re-imaging to VNX Block version 05.33.009.5.236 because of a code deficiency in the Operating Environment for that release.
Updated: December 09, 2025
ID: 000056941
ViPR Dell EMC Storage Resource Management Suite (SRM) shows a blank file‑quota report; quotas are configured, yet the XML API fails with a Java heap space error due to insufficient heap memory on the ControlStation.
Updated: December 09, 2025
ID: 000064529
Software reports a “Media is write protected” error on a Digital Linear Tape (DLT) 1 with DLT4000 tape; the DLT1 can only read, not write; causing a write failure seen as protection.
Updated: December 09, 2025
ID: 000127362
This article explains how to work around the PCI components mismatch error during failover.
Updated: December 05, 2025
ID: 000019342
The Pre-Upgrade Health Check (PUHC) script fails. The tar reports 'This does not look like a tar archive' and header errors, caused by the browser incorrectly decompressing the tar.gz file.
Updated: December 04, 2025
ID: 000052568
How to gather SPCollects from any VNX1 or VNX2 Series array, running OE Release 32 and above, using either Unisphere Client, USM or Navisphere Secure CLI.
Updated: November 11, 2025
ID: 000019534
Agentless import of multiple VNX volumes to PowerStore fail and may result in DataPath Panics.
Updated: November 08, 2025
ID: 000215457
This Knowledge Base acticle details the guidelines for Configuring EMC VNX Systems with SAN Volume Controller and ( SVC ) Storwize V7000 and V5000
Updated: November 06, 2025
ID: 000022439
The following Logical units are not accessible
Updated: November 06, 2025
ID: 000052458
This article is designed to answer frequently asked questions on the topic of Storage Center Operating System (SCOS) Updates.
Updated: November 05, 2025
ID: 000127685
Best practice setting to modify a module parameter for lsi-msgpt3 SAS driver when using SAS Front End connectivity.
Updated: November 04, 2025
ID: 000138029
Dell EqualLogic Downloads for Multipathing Extension Module for VMware vSphere v1.7
Updated: October 22, 2025
ID: 000206904
Dell EqualLogic downloads for Storage Replication Adapter for VMware vCenter Site Recovery Manager v2.3.
Updated: October 22, 2025
ID: 000206472
Datastore creation fails to use NVMe Protocol with Emulex HBA on ESXi 7.0.3.
Updated: October 08, 2025
ID: 000195196
Unable to connect to UNITY via SSH (SSH enabled on UNITY).
In order to proceed with issue analysis connection to Storage Processor via IPMI started.
The IPMI connection through the service ports fails with error:
Error: Unable to establish IPMI v2 / RMCP+ session
Updated: September 10, 2025
ID: 000194884
Storage Customer Notification: pertains to Storage Center OS (SCOS) 6.7, 7.0, and 7.1.1. It contains specific information related to system features and or functionality.
Updated: September 09, 2025
ID: 000137720
SC Storage Customer Notification: Non-Service affecting upgrades may need a controller reset to apply the firmware update.
Updated: September 08, 2025
ID: 000138013
Alerts raised for IP configuration and Port Group (PG) on a management VMkernel adapter of an ESXi host which is configured on a node.
Updated: September 05, 2025
ID: 000179612
Refreshing and Restoring the volume group (volume_group_name) failed.
Updated: September 05, 2025
ID: 000179617
This tutorial explains how to prepare to update a Dell Compellent storage system or SCOS. The steps below to be followed to ensure that the update process runs smoothly.
Updated: September 03, 2025
ID: 000134713
This article explains how BMC and or iDRAC may report network vulnerabilities to scanning software for Storage Center products.
Updated: August 26, 2025
ID: 000129215
SC Storage Customer Notification: Server Cluster Object OS Definition Changes May Cause Removal of Misaligned Volume Mappings.
Updated: August 26, 2025
ID: 000137378
LUN numbers must be consistent across both Storage Center systems when using Live Volume.
Updated: August 21, 2025
ID: 000137742
Receiving alerts of "Only One Path to Device" for one or more disk indexes when using Cross Platform Replication.
Updated: August 21, 2025
ID: 000136589
This policy provides details on the Dell Technologies Security Support Policy for Converged Infrastructure, Midrange and Enterprise Storage, and Storage Networking Products which have reached End of Sales Life (EOL).
Updated: August 19, 2025
ID: 000208328
Refer to the information about the DSA-2019-065 and CVE-2019-3726, also known as the Dell Update Package (DUP) Framework Uncontrolled Search Path Vulnerability.
Updated: August 18, 2025
ID: 000137022
This article discusses Dell EqualLogic SAN HeadQuarters v3.5.1.
Updated: August 13, 2025
ID: 000207245
This article provides switch configuration guidance for Dell PS Series and SC Series SANs. Switch vendors include Arista, Brocade, Cisco, Dell, Huawei, HP, Juniper, and others.
Updated: July 31, 2025
ID: 000124943