Skip to main content
PowerPath for AIX image

PowerPath for AIX

PowerPath for AIX

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 73 shown
73 out of 73 shown

A slow blinking amber light showing internally from the switch model DS6620B-V2, not from the switch panel, is confirmed by Brocade to be the LED from the eUSB card (on the motherboard).
Updated:  November 15, 2023 ID: 000217788

This article explains what asb:iopf stands for in powermt display dev=all?
Updated:  April 24, 2021 ID: 000047102

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated:  January 09, 2026 ID: 000185734

When you downgrade PowerPath from 6.x to 5.x, you need to put aside the PowerPath 5.x saved configuration files in advance.
Updated:  December 29, 2025 ID: 000019542

powermt commands fail with "ERROR: Device Lam claim failed"
Updated:  December 22, 2025 ID: 000055720

Trying to boot from San using Powerpath and a Dell EMC Unity array in and AIX Enviroment
Updated:  December 12, 2025 ID: 000052575

This article provides the fix when the Windows host cannot see LUNs on Unity Array after installation of PowerPath 6.1.
Updated:  December 12, 2025 ID: 000052798

Write are failing from time to time, leading to an LVM error (LVM_IO_FAIL - EWRPROTECT) for no obvious reason, as if the device was "write protected." The error was reported as: "AIX shows disk operation error on array with PowerPath. No error showed in the array…."
Updated:  December 12, 2025 ID: 000072366

Event 4 appears in Viewer, reporting Corporation () PowerPath MPAPI error after upgrade to 5.7 SP2. MPAPI (Powermt, host-agent, Powermig) causes error. No impact on PowerPath cluster.
Updated:  December 10, 2025 ID: 000055944

When PowerPath for Windows version 6.1 is installed on Windows Server 2016, validation alerts indicate many drivers have dates earlier than the OS, because the PowerPath release predates the OS.
Updated:  December 09, 2025 ID: 000062991

This article notes how PowerPath on Red Hat Enterprise Linux 2.1 or 3 can cause SAN access conflicts and block storage software. The cause is the PowerPath driver and services.
Updated:  December 04, 2025 ID: 000132251

Following a new installation of Oracle ASM 11 g (or above) or an upgrade of Oracle ASM, no disks are showing up as available ASM disks.
Updated:  November 17, 2025 ID: 000050160

This article explains how to assign an Initial Company Administrator.
Updated:  November 14, 2025 ID: 000374134

The purpose of this KB article is to provide common information about ESXi issues and the steps to troubleshoot them.
Updated:  November 12, 2025 ID: 000205090

AIX LPM fails when trying to move and LPAR from Frame A to Frame B.
Updated:  November 04, 2025 ID: 000064368

In an NPIV configuration with two virtual HBA, when one virtual HBA goes down, and although there is one path left for the I/Os, LVM_IO_FAIL are logged in errpr with ERROR CODE AS DEFINED IN sys/errno.h set to 22 (EINVAL). Because of these LVM errors, the application using the volume crashes. The issue could also occur in a non NPIV environment.
Updated:  November 04, 2025 ID: 000081958

PPME migration seems to have hung Disk Management and PowerPath 6.2 on the B node of an Active/Active cluster. Node A is the one that has 10 handles setup (no sync yet) but node B is showing high I/O across all disks for some reason.
Updated:  November 04, 2025 ID: 000050087

When the host is rebooted, NMP manages some or all VPLEX LUNs (instead of PowerPath/VE).
Updated:  October 23, 2025 ID: 000051943

What is the maximum number of LUNs (Logical Unit Number) that can be presented? What is the maximum number of Paths per LUN? What is the Maximum Partition size on Microsoft Windows?
Updated:  October 22, 2025 ID: 000019117

This article explains how to promote Company Administrators.
Updated:  October 21, 2025 ID: 000374126

Server hung while PPME migration was in progress at which TargetLUfault errors are received in powermig info.
Updated:  October 20, 2025 ID: 000054845

PowerPath 6.0 (or earlier) is installed and configuring VMAX devices fine. However, after upgrading to PowerPath 6.1, configuring devices is failing with no error message. The devices are just not configured for PowerPath and no pseudodevice is created.
Updated:  October 17, 2025 ID: 000170122

Creating host using mksysb and native drivers result in reserve conflicts after Dell EMC ODMs installed (boot from SAN)
Updated:  October 17, 2025 ID: 000064324

PowerPath IBM AIX ODM reserve lock attributes not converting to reserve_policy.
Updated:  October 17, 2025 ID: 000171373

PowerPath 7.0 introduces a new feature, "flaky path reporting". this article is an attempt to explain how this feature really works and what can be expected.
Updated:  October 17, 2025 ID: 000020123

Microsoft Failover cluster resources go offline during a volume expansion in PowerPath for Windows 6.1.
Updated:  October 17, 2025 ID: 000064173

With PowerPath 6.4 for AIX, the emc_reserve_v3.sh script fails with "PowerPath version Version not >= 5.5".
Updated:  October 17, 2025 ID: 000050278

If the reboot of the SC is taking more than 15 seconds, PowerPath will report an "all_paths_dead" situation, resulting in LVM errors and/or AIX server crash
Updated:  October 17, 2025 ID: 000055740

Following a Powerpath upgrade, VTD with VMAX3 devices backing devices remain defined.
Updated:  October 17, 2025 ID: 000063898

to migrate data from one kind of array to another, there are different tools available either involving the host or completed on the SAN directly. This article is presenting splitvg as an alternate method to migrate data while keeping a copy on the source array.
Updated:  October 17, 2025 ID: 000064334