Server Administrator Version 7.4 Messages Reference Guide

PDF

Drive Events

The drive event messages monitor the health of the drives in a system. These events are generated when there is a fault in the drives indicated.

Table 1. Drive Events
Event Message Severity Cause
Drive <Drive #> asserted fault state. Critical This event is generated when the specified drive in the array is faulty.
Drive <Drive #> de-asserted fault state. Information This event is generated when the specified drive recovers from a faulty condition.
Drive <Drive #> drive presence was asserted. Information This event is generated when the drive is installed.
Drive <Drive #> predictive failure was asserted. Warning This event is generated when the drive is about to fail.
Drive <Drive #> predictive failure was deasserted. Information This event is generated when the drive from earlier predictive failure is corrected.
Drive <Drive #> hot spare was asserted. Warning This event is generated when the drive is placed in a hot spare.
Drive <Drive #> hot spare was deasserted. Information This event is generated when the drive is taken out of hot spare.
Drive <Drive #> consistency check in progress was asserted. Warning This event is generated when the drive is placed in consistency check.
Drive <Drive #> consistency check in progress was deasserted. Information This event is generated when the consistency check of the drive is completed.
Drive <Drive #> in critical array was asserted. Critical This event is generated when the drive is placed in critical array.
Drive <Drive #> in critical array was deasserted. Information This event is generated when the drive is removed from critical array.
Drive <Drive #> in failed array was asserted. Critical This event is generated when the drive is placed in the fail array.
Drive <Drive #> in failed array was deasserted. Information This event is generated when the drive is removed from the fail array.
Drive <Drive #> rebuild in progress was asserted. Information This event is generated when the drive is rebuilding.
Drive <Drive #> rebuild aborted was asserted. Warning This event is generated when the drive rebuilding process is aborted.
Drive <Drive #> is installed. Information This event is generated when the drive is installed.
Drive <Drive #> is removed. Critical This event is generated when the drive is removed.
Fault detected on drive <Drive #>. Critical This event is generated when the specified drive in the array is faulty.